10. Redundancy of BCUs, CSUs, and MSUs
283
redundancy force-switchover
Replaces the active system with the standby system in a redundant configuration.
Syntax
redundancy force-switchover
Input mode
User mode and administrator mode
Parameters
None
Example
The following shows an example of replacing the active system with the standby system in a
redundant configuration:
>redundancy force-switchover Press the
Enter
key.
Display items
None
Impact on communication
•
Some packets might be lost temporarily while the system is being replaced.
•
To reconfigure network information after the system is replaced, communication might be lost
temporarily.
Response messages
Table 10-3:
List of response messages for the redundancy force-switchover command
Message
Description
Can't accept command (Active BSU is nothing).
There is no active BSU.
Can't accept command (system is busy).
The command cannot be accepted (because the system is busy).
Re-execute the command later.
Can't execute this command in standby system.
This command cannot be executed on a standby system.
Can't execute.
The command could not be executed. Re-execute the command.
Now switchover executing.
The system is being switched.
Now synchronize executing.
The
synchronize
command is being executed. Re-execute the
redundancy force-switchover
command after the
synchronize
command completes.
Now, configuration discord.
Configurations for the active system and for the standby system do
not match.
Now, configuration file is editing.
The configuration file is being edited or synchronized. If it is being
edited, quit editing and then re-execute the command. If it is not being
edited, wait a while, and re-execute the command.
Note, however, that this message might be displayed temporarily if
the standby system is being started.
Now, configuration file is writing.
The configuration file is being saved or synchronized. If it is being
saved, re-execute the command after the configuration is saved. If it
is not being saved, wait a while, and re-execute the command.
Note, however, that this message might be displayed temporarily if
the standby system is being started.
Summary of Contents for AX6300S series
Page 4: ......
Page 10: ......
Page 16: ......
Page 24: ......
Page 25: ...9 PART 2 Filters Chapter 2 Filters show access filter clear access filter ...
Page 34: ......
Page 49: ...3 Access List Logging 33 Notes None ...
Page 80: ...4 QoS 64 Notes None ...
Page 112: ......
Page 148: ......
Page 202: ......
Page 242: ......
Page 264: ......
Page 294: ......
Page 304: ......
Page 332: ......
Page 377: ...12 VRRP 361 Notes None ...
Page 378: ......
Page 388: ...13 IEEE 802 3ah UDLD 372 file in advance if necessary ...
Page 390: ......
Page 406: ......
Page 436: ...15 CFM 420 Notes None ...
Page 440: ...15 CFM 424 Notes None ...
Page 466: ...16 SNMP 450 appears and the MIB cannot be acquired ...
Page 483: ...467 Chapter 17 sFlow show sflow clear sflow statistics restart sflow dump sflow ...
Page 490: ......
Page 497: ...18 LLDP 481 Notes None ...
Page 520: ......