ATS9462 User Manual
39
Restrictions
To ensure proper master/slave operation of your ATS9462
digitizers, you must observe the following restrictions:
•
All Master/Slave digitizers must be installed in
adjacent slots, i.e. there should be no gap between
the digitizers that are to be configured as a
Master/Slave system
Good Installation
Bad Installation
•
You must connect the appropriate SyncBoard to all of
the ATS9462 digitizers in your system. Note that all
SyncBoards are polarized, so you cannot make a
mistake in inserting them
•
If you are using fewer than the maximum number of
digitizers allowed by the SyncBoard, make sure that
the connector labeled “M” (Master) on the SyncBoard
is connected to one of the ATS9462 digitizers. Any
over-hang of the SyncBoard should be beyond the
last slave board in your system