Albalá Ingenieros | Manual
AAD3014C01
The following functions of the AAD3014C01 can be performed remotely:
- Signal level adjustment.
- Configuration of the signal absence and overload detectors.
- Supervision of the status of the error detectors.
4.3.1. Details of the AAD3014C01 registers
The AAD3014C01 module provides control and status registers that can be read and
written by means of specific commands described in the communication control
module user manuals.
The parameter information grouped in the CONTROL or RAM sections is stored in
volatile memory. Any modifications to the parameters will be lost when the module
power supply is disconnected unless the "EEPROM Save" button within the software
has been pressed.
The STATUS section parameters are read-only and cannot be modified.
The parameters that can be controlled and supervised remotely for each version of
the firmware are listed below:
VERSION 2.X
CONTROL
Name
add
ext
msk
snmp trap
Description
MONO
0x00
0x01
Y
N
Allows summing R&L to make a monophonic channel
0=Disabled, 1=Enabled
SILENCE_MASK_R
0x01
0x01
N
N
Allows masking silence fail right channel
0=Disabled, 1=Enabled
OVERLD_MASK_L
0x01
0x02
N
N
Allows masking silence fail left channel
0=Disabled, 1=Enabled
OVERLD_MASK_R
0x01
0x04
N
N
Allows masking overload fail right channel
0=Disabled, 1=Enabled
SILENCE_MASK_L
0x01
0x08
N
N
Allows masking overload fail left channel
0=Disabled, 1=Enabled
GAIN_R
0x02
0xFF
Y
N
Allows adjusting right channel gain
= x/2-96 dB
GAIN_L
0x03
0xFF
Y
N
Allows adjusting left channel gain
= x/2-96 dB
OVL_THR_LEVEL
0x04
0xFF
Y
N
Overload threshold level
= x/2 dBu (-128=<- ? dBu)
SIL_THR_LEVEL
0x05
0xFF
Y
N
Silence threshold level
= x/2 dBu (-128=<- ? dBu)
NO_SIG_TOUT
0x06
0xFF
Y
N
Silence timeout
= x s
STATUS
Name
add
ext
msk
snmp trap
Description
SILENCE_R
0x01
0x01
Y
Y
Silence fail right channel
0=OK,1=Fail
SILENCE_L
0x01
0x02
Y
Y
Silence fail left channel
0=OK,1=Fail
OVERLOAD_R
0x01
0x04
Y
Y
Overload fail right channel
0=OK,1=Fail
OVERLOAD_L
0x01
0x08
Y
Y
Overload fail left channel
0=OK,1=Fail
20
Summary of Contents for AAD3014C01
Page 2: ...AAD3014C01 ...
Page 4: ...AAD3014C01 ...
Page 7: ...Albalá Ingenieros Manual AAD3014C01 1 3 Block diagram 7 ...
Page 8: ...Albalá Ingenieros Manual AAD3014C01 AAD3014C01 8 ...
Page 16: ...Albalá Ingenieros Manual AAD3014C01 AAD3014C01 16 ...
Page 22: ...Albalá Ingenieros Manual AAD3014C01 AAD3014C01 22 ...
Page 24: ...Albalá Ingenieros Manual AAD3014C01 AAD3014C01 24 ...
Page 25: ...Albalá Ingenieros Manual AAD3014C01 6 REGULATIONS 25 ...
Page 26: ...Albalá Ingenieros Manual AAD3014C01 AAD3014C01 26 ...