background image

Albalá Ingenieros | Manual 

AVD3003C01

3. INSTALLATION

THE AVD3003C01 MODULE CONTAINS ELECTRONIC DEVICES SENSITIVE TO
ELECTROSTATIC DISCHARGE. Always use antistatic bags clearly identified
with a high degree of shielding for storage and transportation.

The AVD3003C01 module is composed of two parts: one AVD3003P01 main board and
one XVD3000P03 rear board. Both parts must be installed in a UR3000 or UR3100
mounting frame following the instructions in the corresponding section of this chapter.

3.1. Initial inspection

Verify that the package has been properly handled during transport. After opening the
packaging, check that one AVD3003P01 main board and one XVD3000P03 rear board are
inside.

You must notify your Albalá Ingenieros distributor or dealer of any damage or defects
observed.

Follow the instructions in this manual to install this module in the mounting frame.

3.2. Safety instructions

• This equipment must be connected to a mains outlet with a protective

earth connection. Never use extension cords that do not have protective
earthing connection. The lack of an effective electrical connection between
the ground pin in the mains input connector of the equipment and the
protective earth of the electrical power distribution can cause serious harm.

• All modules of the Albalá Ingenieros TL3000 terminal line can be

hot-plugged or unplugged without suffering any damage or affecting the
processes that are currently taking place in other modules in the same
mounting frame. When a module is installed in an empty bay of a mounting
frame, it is necessary to mount the rear board that is part of that module.

Prior to installing this board, the mounting frame must be disconnected
from the power supply network.

 This is required because in addition to the

risk of electrocution for the person handling the device it is possible that a
high instantaneous current coming from the power supply could damage
the connectors and components of the mounting frame and/or the rear
board.

9

Summary of Contents for AVD3003C01

Page 1: ...AVD3003C01 TRIPLE 1 LOOP THROUGH INPUT TO 2 OUTPUTS ANALOG VIDEO DISTRIBUTOR Version 1 0 Albalá Ingenieros S A Medea 4 28037 Madrid Spain 22 September 2016 Albalá Ingenieros S A All rights reserved ...

Page 2: ...AVD3003C01 ...

Page 3: ... 7 3 INSTALLATION 9 3 1 Initial inspection 9 3 2 Safety instructions 9 3 3 Environmental considerations 10 3 4 Power considerations 10 3 5 Installing the module in the mounting frame 10 3 6 Interconnection 12 3 6 1 Analog video connections 12 4 OPERATION 15 4 1 Front panel description 15 4 2 Module remote control and supervision 16 5 GLOSSARY 17 6 REGULATIONS 19 7 VERSIONS 21 ...

Page 4: ...AVD3003C01 ...

Page 5: ...outputs per channel AVD3003C03 Triple video distributor with loop through inputs two outputs per channel and single adjustment equalizers for various cable types 1 2 Features Triple analog video distributor Includes three identical sections Each section provides one loop through input and two outputs Wide bandwidth One UR3000 mounting frame can house up to 12 AVD3003C01 modules If power supply red...

Page 6: ...Albalá Ingenieros Manual AVD3003C01 1 3 Block diagram 6 ...

Page 7: ...tor BNC Impedance 75 Ω 1 Return loss 35 dB up to 10 MHz Number of outputs 2 per section Separation between outputs 45 dB at fsc DC voltage 10 mV Analog video signal Input to output coupling DC Input to output delay 3 5 ns 1 ns Dynamic range 1 5 V Bandwidth 3 dB 80 MHz Differential gain 0 1 Differential phase 0 1 Tilt 0 2 Chrominance to luminance delay 1 ns S N ratio unweigthed with ref 0 7 VRMS 70...

Page 8: ...Albalá Ingenieros Manual AVD3003C01 AVD3003C01 8 ...

Page 9: ...ns This equipment must be connected to a mains outlet with a protective earth connection Never use extension cords that do not have protective earthing connection The lack of an effective electrical connection between the ground pin in the mains input connector of the equipment and the protective earth of the electrical power distribution can cause serious harm All modules of the Albalá Ingenieros...

Page 10: ...l the AVD3003C01 module with the rear board in the mounting frame are 1 Disconnect all power cords from the power supplies of the mounting frame 2 Remove the blank panels covering the front and rear of the empty bays chosen for installing the AVD3003C01 in the mounting frame 3 Install the XVD3000P03 rear board ensuring that its 12 pin connectors are properly aligned with the mounting frame s matin...

Page 11: ...Albalá Ingenieros Manual AVD3003C01 Details for installation of the module in 3 RU mounting frames Details for installation of the module in 1 RU mounting frames 11 ...

Page 12: ...OUT1 A OUT2 A OUT1 B OUT2 B OUT1 C OUT2 C all for analog video signals The rear interconnection board is not designed to withstand mechanical stress The wiring must be fastened properly to the frame where the mounting frame is housed to prevent the rear board from supporting the weight of the cables 3 6 1 Analog video connections The analog video inputs use two BNC connectors configured in loop th...

Page 13: ...3C01 If the loop through input LOOP X is not used to send signal to another piece of equipment then it should be terminated with 75 Ω For analog video connections a coaxial cable with 75 Ω of characteristic impedance must be used 13 ...

Page 14: ...Albalá Ingenieros Manual AVD3003C01 AVD3003C01 14 ...

Page 15: ...ignificance of the front panel indicators of the AVD3003C01 module and their remote control and monitoring ability 4 1 Front panel description The appearance of the front panel and the elements it contains are shown in the following illustration Front panel of the AVD3003C01 15 ...

Page 16: ...Albalá Ingenieros Manual AVD3003C01 4 2 Module remote control and supervision The AVD3003C01 CANNOT be remotely controlled or supervised 16 ...

Page 17: ...Albalá Ingenieros Manual AVD3003C01 5 GLOSSARY 17 ...

Page 18: ...Albalá Ingenieros Manual AVD3003C01 AVD3003C01 18 ...

Page 19: ...Albalá Ingenieros Manual AVD3003C01 6 REGULATIONS ITU R BT 470 6 1998 Conventional analogue television systems See also ITU R BT 1700 SMPTE 170M 19 ...

Page 20: ...Albalá Ingenieros Manual AVD3003C01 AVD3003C01 20 ...

Page 21: ...Albalá Ingenieros Manual AVD3003C01 7 VERSIONS Ver Date Description 0 0 13 06 2013 Preliminary Version 1 0 22 09 2016 First version ...

Page 22: ...Albalá Ingenieros S A Medea 4 28037 Madrid Spain 34 913274453 www albalaing com info albalaing com ...

Reviews: