Albalá Ingenieros | Manual
DVM3001C02
The following functions of the DVM3001C02 can be performed remotely:
- Configuration of the conversion to composite video (vertical interval blanking, filter
type, removal of chrominance).
- Configuration of the module in single or dual mode.
- Supervision of the presence and status of the input signals.
4.2.1. Details of the DVM3001C02 registers
The DVM3001C02 module provides control and status registers that can be read and
written by means of specific commands described in the communication control
module user manuals.
The parameter information grouped in the CONTROL or RAM sections is stored in
volatile memory. Any modifications to the parameters will be lost when the module
power supply is disconnected unless the "EEPROM Save" button within the software
has been pressed.
The STATUS section parameters are read-only and cannot be modified.
The parameters that can be controlled and supervised remotely for each version of
the firmware are listed below:
VERSION 1.X
CONTROL
Name
add
ext
msk
snmp trap
Description
VBI_PASS_A
0x00
0x01
Y
N
Allows selecting if the VBI is blanked (Section A)
0=Blank, 1=Pass
VBI_PASS_B
0x00
0x02
Y
N
Allows selecting if the VBI is blanked (Section B)
0=Blank, 1=Pass
CHROMA_A
0x00
0x04
Y
N
Allows disabling chroma (Section A)
0=Off, 1=On
CHROMA_B
0x00
0x08
Y
N
Allows disabling chroma (Section B)
0=Off, 1=On
LUMA_FILTER_A
0x00
0x10
Y
N
Allows selecting luminance filter (Section A)
0=Notch, 1=Flat
LUMA_FILTER_B
0x00
0x20
Y
N
Allows selecting luminance filter (Section B)
0=Notch, 1=Flat
CUSTOM_FILTER_A
0x00
0x40
Y
N
Allows selecting a custom luminance filter (Section A)
0=Custom, 1=Standard
CUSTOM_FILTER_B
0x00
0x80
Y
N
Allows selecting a custom luminance filter (Section B)
0=Custom, 1=Standard
MODE
0x01
0x04
Y
N
Allows selecting module operating mode
0=Single, 1=Dual
NO_SIG_A_MASK
0x02
0x01
N
N
Allows masking no signal fail (Section A)
0=Disabled, 1=Enabled
NO_SIG_B_MASK
0x02
0x02
N
N
Allows masking no signal fail (Section B)
0=Disabled, 1=Enabled
MAX_EQ_A_MASK
0x02
0x04
N
N
Allows masking maximum equalization fail (Section A)
0=Disabled, 1=Enabled
MAX_EQ_B_MASK
0x02
0x08
N
N
Allows masking maximum equalization fail (Section B)
0=Disabled, 1=Enabled
UNLOCK_A_MASK
0x02
0x10
N
N
Allows masking unlock fail (Section A)
0=Disabled, 1=Enabled
UNLOCK_B_MASK
0x02
0x20
N
N
Allows masking unlock fail (Section B)
0=Disabled, 1=Enabled
20
Summary of Contents for DVM3001C02
Page 2: ...DVM3001C02 ...
Page 4: ...DVM3001C02 ...
Page 7: ...Albalá Ingenieros Manual DVM3001C02 1 3 Block diagram 7 ...
Page 8: ...Albalá Ingenieros Manual DVM3001C02 DVM3001C02 8 ...
Page 16: ...Albalá Ingenieros Manual DVM3001C02 DVM3001C02 16 ...
Page 24: ...Albalá Ingenieros Manual DVM3001C02 DVM3001C02 24 ...
Page 26: ...Albalá Ingenieros Manual DVM3001C02 DVM3001C02 26 ...