Part # 6410T0008
Rev.F
-4-
ACS-50 ELECTRICAL PRACTICES
WARNING
THE ACS-50 CONTROL BOX CONTAINS HIGH VOLTAGE. QUALIFIED ELECTRICAL
PERSONNEL SHOULD PERFORM THE FOLLOWING PROCEDURES ONLY. WIRING AND
CONTROL PANEL MOUNTING (ANCHORING) MUST MEET ALL LOCAL, STATE, FEDERAL,
INTERNATIONAL, OR OTHER GOVERNMENT AGENCY CODES.
FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH.
THE CONTROL PANEL SHOULD BE MOUNTED APPROXIMATELY 48 INCHES OFF OF THE
FINISHED FLOOR FOR EASE OF TROUBLESHOOTING AND SERVICE. WIRING FOR POWER,
(MOTOR AND BRAKE) SHOULD BE A MINIMMUM OF 14AWG. FOR CONTROL
WIRING,
SHOULD BE A MINIMUM OF 18 AWG.
1.
NOTE
:
REFERENCE FIGURE BELOW AS A GUIDE FOR MAKING THESE WIRE
CONNECTIONS TO THE UNIQUE WAGO STYLE TERMINALS.
WARNING
A SEPERATE FUSED DISCONNECT IS REQUIRED FOR
PROTECTION OF THE DRIVE AND CONTROL SYSTEM.
THIS DISCONNECT IS TO BE SUPPLIED BY OTHERS. THE
DISCONNECT PROVIDED ON THE CONTROL BOX IS NON-
FUSED
.
ALL CONDUIT PENATRATIONS MUST BE IN THE
BOTTOM OF THE CONTROL PANEL ENCLOSURE. TOP
PENATRATION OF THE ENCLOSURE CAN VOID
WARRANTY.
1. Insert a mini screwdriver in the operating
slot, located on the top of the terminal, up to the
stop.
2. The screwdriver blade holds the clamping
spring open automatically so that the conductor
can be introduced into the clamping unit
3. Insert the wire into the block.
4. Withdraw the screwdriver – the conductor is
automatically clamped.
Summary of Contents for ACS-50
Page 5: ...Part 6410T0008 Rev F 5 ACS50 Control Panel Interior Single speed ...
Page 7: ...Part 6410T0008 Rev F 7 Figure 7 Single Speed Motherboard ...
Page 8: ...Part 6410T0008 Rev F 8 Figure 8 Two Speed Motherboard ...
Page 34: ...Part 6410T0008 Rev F 34 ACS50 Contactless Safety Edge Wiring if equipped ...
Page 35: ...Part 6410T0008 Rev F 35 Blanking Light Curtain Photocell Wiring ...
Page 36: ...Part 6410T0008 Rev F 36 ACS 50 Floor Loop 2Posi Selector Switch ...