RCA L
Version 2.0
8
Product Description
2.2.1 Additional Safety systems
Depending on the kind of application it may be useful to have additional sensors as safety
features. This is especially true for a door with a high volume of human traffic or with low
sized doors with a height under 10 feet (3m).
Albany Door Systems offers a variety of safety systems for high-speed doors. Some
examples could be any of the following: Light beam barriers, motion detectors, induction
loops. For any other electrical requirement contact us at the factory.
2.3 Drives
The Re-Coil-Away is operated with an electrical drive. Drive side is chosen by the end-user.
The drive system has a 1-speed operator. The drive systems come in 3 different operating
voltages: 208 VAC, 460 VAC, and 575 VAC.
2.4 Technical Data
Door principle:
Roll door
Running direction:
Vertical
Application:
External door
(also applicable as interior door)
Maximum Sizes:
18’ wide x 18’ high
Maximum opening speed:
18 inches per second @ 8 feet
(Depends on door size)
Maximum Closing speed:
18 inches per second @ 8 feet
(Depends on door size)
Fitting position:
Interior or external mounting
Drive:
Electrical
Electric Power:
208VAC, 460VAC, 575VAC
Maximum Horse power:
2.0 H.P.
Control unit:
Built-in operator controls
Control voltage
24VDC
Motor protection category:
IP54 - NEMA 12
Door frame:
Painted Steel
Curtain:
SBR, EPDM
Door dimensions and fitting space
See enclosed technical drawing
Fixing points:
See fixing drawings
Technical changes resulting of product maintenance are subject to alterations
Summary of Contents for RCA L
Page 1: ...RCA L Version 1 0 RCA L Owner s Manual ...
Page 2: ...RCA L Version 2 0 2 1 2 3 3 4 5 6 7 Safety 8 7 Components ...
Page 28: ...RCA L Version 2 0 28 6 4 2 Operator Troubleshooting Service Repair ...
Page 29: ...RCA L Version 2 0 29 Service Repair ...
Page 32: ...RCA L Version 2 0 32 6 5 4 Replacing the operator brake band Service Repair ...
Page 33: ...RCA L Version 2 0 33 6 5 5 Adjusting the operator brake band Service Repair ...
Page 36: ...RCA L Version 2 0 36 RCA L Architectural Up to including 12 x 12 ...
Page 37: ...RCA L Version 2 0 37 RCA L Architectural Over 12 x 12 ...