23
Manuale Uso MP NIWA - Code 10011873 - Edition 1 - 03/2008
Instructions for operation
English
Example of Filtration cycle settings
1) Press the
FILTRATION
key
The display shows
Fdx
(where “
x
” indicates the
duration of the fi ltration cycle in hours).
2) Enter the individual
Fd
(duration) settings using
the
UP
and
DOWN
keys (e.g.
Fd = 6
).
3) Confi rm the setting by pressing the
FILTRATION
key.
4) The display shows
Fsx
(where “
x
” indicates the
delayed-start time in hours).
5) Enter the delay time by pressing the
UP
/
DOWN
keys (e.g.
Fs=4
).
6) Press the
FILTRATION
key to confi rm the
setting.
If the function is programmed in this way at, for
example, 2:30 p.m., the fi ltration programme will
start at 6:30 p.m. (i.e. exactly 4 hours after the
programme is set, since Fs=4 was entered). The
programme will operate until 0:30 a.m. (because
Fd=6 sets the duration to 6 hours).
Excessive temperature during the fi ltration
cycle
If the temperature of the water remains more
than 1°C higher than the temperature selected
by the user for three hours, the fi ltration cycle is
interrupted until the temperature falls to at least
1°C lower than the selected temperature or until
the moment at which the subsequent fi ltration
cycle commences.
N.B.:
1) Filtration cycles with a duration of less than 3
hours are carried out completely irrespective of
the temperature of the water.
2) If the duration of the fi ltration cycle is set to more
than 3 hours, then at least 3 hours of fi ltration are
always completed.
3) The fi ltration cycle starts even if the temperature
of the water is higher than the set point. If the
temperature remains too high, the cycle may
be interrupted after three hours have been
completed.
Main functions
Messages and fl ashing signals
The triangles in the lower section of the display,
which light when a programme is in operation,
may also fl ash.
This may indicate one of two conditions:
1) Normal operating mode, but at low speed (e.g.
the two-speed pump).
2) Function temporarily interrupted.
Adjusting the temperature of the water
The temperature of the water in the Mini-pool can
be adjusted so that it remains within about ±0.5°C
of the temperature selected by the user.
When the temperature of the water falls to 1°C lower
than the temperature selected by the user, the heater
and the circulation pump switch on automatically to
restore the water to the correct temperature.
The heater and the circulation pump switch off as
soon as the water reaches the temperature entered
by the user.
Characteristics of this parameter:
- limit settings:
-
minimum 15°C
-
maximum 40°C
- setting intervals:
0.5°C
- initial setting:
35°C
- when the appliance is switched on, the
last value entered is restored.
If the
ECO
programme has been selected, the target
temperature is 10°C lower than the value entered by
the user, as described above for the
ECO
function.
When the system is in standby mode, the value
shown on the display is the temperature of the
water in the Mini-pool.
Press the UP or DOWN key once: the temperature
selected by the user is displayed.
Press the UP or DOWN keys again to increase or
decrease the desired water temperature.
If neither key is pressed for 5 seconds, the system
returns to standby mode and the actual temperature
of the water is again displayed.
5