Manuale Uso MP NIWA - Code 10011873 - Edition 1 - 03/2008
Instructions for operation
English
Stand-By function
The
Stand-By
function allows the user to disactivate
all the programmes for a period of 60 minutes,
so that routine maintenance can be carried out
without disconnecting the mini-pool from the
power supply.
To start this function, press and hold down the
Filtration
key for fi ve seconds.
When the
Stand-By
function is in operation, “
Sby
”
and the time-to-elapse are shown alternately on
the display.
The
Stand-By
function terminates:
1) When the cycle time has elapsed
2) If the Filtration key is pressed and held down
for fi ve seconds
3) If the control unit is switched off
The
Stand-By
function suspends the commencement
of the fi ltration cycle, which, if selected, will take place
40 minutes after the end of the
Stand-By
period.
The
Stand-By
function does not block the operation
of the anti-freezing function (see “Smart Winter
Mode”), which will be performed in the normal
way if necessary.
Increasing the programmed maximum
temperature
This function allows the user to increase the
maximum temperature that the water in the
mini-pool can reach from the standard maximum
temperature of
40°C
to
42°C
, in gradual, controlled
steps.
1) Posible temperature intervals:
minimum 0.5°C
,
maximum 2.0°C
;
2)
Regulation
interval:
0.5°C
;
3)
Initial
value:
0.5 hours
;
4) Temperature when the appliance is switched
on: the last temperature selected is restored.
Proceed as follows:
1) Enter the maximum set-point for the
temperature (i.e.
40°C
), following the normal
procedure.
2)
Press
“
Up
” for fi ve seconds. The display will
show
Orx.x
, where
x.x
is the value to be
entered.
3)
Press
the
Up
or
Down
keys to increase or
decrease the setting.
4) To exit selection mode, either press any key
(other than the
Up
and
Down
keys), or wait
for fi ve seconds.
After entering an increase for the maximum set-
point, simply press
Up
or
Down
(it is not necessary
to hold the key down for fi ve seconds).
To reset the set-point to a temperature that is within
normal limits, proceed as follows:
1)
Press
Down
until the minimum value is
displayed (display:
Or0.5
)
2)
Press
the
Down
key again. The display will
show the set-point, and the system returns
to the normal programming procedure.
Functions not directly selectable by the user
Heater
During normal operation, the heater is switched
on when necessary for the water temperature
regulation process.
Heating of the water requires the
coordinated
activation / disactivation of the heater and the
pump
(the pump ducts water through the heater
in order to prevent overheating).
When the heater is switched on, a triangle located
above the thermometer symbol lights.
The following phases are carried out when the
heating system is in operation
1) The circulation pump switches on
2)
The
fl ow of water is checked
3) The heater switches on
When the heating system is switched off :
1) The heater is disconnected from the power
supply
2) After 30 seconds, the circulation pump
switches off in order to allow the heating
element to cool.
Circulation pump
Ther circulation pump is almost always in operation
during normal use (if the tub is in use, or during the
fi ltration cycle etc.), except when interrupted by
alarm
conditions or during the
ECO
cycle (unless
heating of the water is required).
Sanitization ozonizer
This type of ozonizer is used to sanitize the water,
and therefore diff ers from the system used during
the Airpool function, which is dedicated to the
well-being of the user, blending ozone and air to
produce a relaxing, tonic massage eff ect.
This ozonizer switches on only when the circulation
pump is in operation.