4.

Initial water adjustments

3.

First days of maintenance

During the first 10-15 days your pool system will require more attention and the following care:

 Make sure the pH remains on the ideal level (7,2 - 7,5). If the pH is unusually unstable and uses a lot of acid check the alkalinity (recommended levels 
between 80 y 125 ppm). 

2  The pool must be vacuumed and the skimmers cleaned whenever necessary to ensure perfect water conditions.

REMEMBER that the system requires a certain amount of time to adapt to your swimming pool and will require additional chemicals during the first 
3-5 days.

Cleaning the titanium cell 

If necessary, carry out a monthly visual inspection. To clean the cell:

Remove the cell from its support (after turning off the filtration system and closing off the necessary valves).

2  Place the cell for no more than 10 minutes in 15% hydrochloric acid (1,5 l of acid for each 8,5 l of water).
3  Once the incrustations have softened remove with a hose to complete cleaning the cell.

DO NOT USE METALIC OR SHARP OBJECTS TO REMOVE INCRUSTATIONS. Scratching the edges or surface of the cell will make it vulnerable to 
chemicals, deteriorate the cell and cancel the guarantee.

Water adjustments

Adjust the alkalinity between 90 and 110 ppm’s. 

2  Adjust the pH between 7,2 y 7,5. 
3  Adjust the chlorine between 1 y 1,5 ppm’s.

   In case the water is supplied from a well: Shock 

chlorination with trichloroisocyanuric acid (2 kg / 
50 m

3

 of water).

Adding salt to the water / conductivity

 We recommend to add 5-6 g of salt (without iodine) for each liter of water in your 
swimming pool (5 to 6 kg NaCl per m

3

 water). 

2   Open the bottom valve of your swimming pool and add the salt directly to your 

swimming pool water. Let the circulation pump run during the first 24 hours.

   The system may operate while the salt is dissolving and will operate without problems 

with salt concentrations from 2,5 g/l to 50 g/l.

    In pools with strong insolation, it’s necessary to add 40 gr/m

3

 of stabiliser (isocyanuric acid).

General maintenance

 The pool must be vacuumed as usual and the skimmers emptied whenever necessary.

2   FILTER BACKWASHING: The system requires only occasional filter cleaning; once every 20 days should be sufficient (providing  

the filter pressure does not exceed 1 bar, in which case a filter cleaning may be necessary). 
VERY IMPORTANT: Make sure the cell is off while cleaning the filter. If the system controls the filtration pump, use the option “filter cleaning” of the 
programmed filtration mode. See section 5– Filtration / Filter Cleaning of the General Installation Guide.

3   ADDING NEW WATER: Always through the skimmers so that the new water passes through the system before entering the pool. Remember to 

add the necessary salt (6 gr) per added liter of water.

4  In winter changing the pool water is not recommendable. We recommend that the system runs 2-3 times per week (2-3 hours per day).
5   DOSING PUMPS: Check regularly to ensure that the container contains liquid to prevent the dosing pump of running dry. The dosing pump 

requires maintenance (SEE INSTRUCTIONS ON BOX).

6   pH PROBES / redoX / CONDUCTIVITY: Probes must be cleaned whenever necessary (check every 5-6 months). To clean the probe insert in 

distilled water (clear liquid). After each cleaning the probes must be calibrated. Also: the probes should never dry out and must be kept wet if stored 
(when emptying the pool for winterizing, make sure to store the measuring head in water). 

Fortnightly checks

Monthly checks

Free chlorine:

1,0 - 2,0 ppm

pH:

7,2 - 7,5

Total alkalinity (tac) pH:

80 - 120 ppm

Cyanuric acid:

30 - 50 ppm

Salt concentration:

4.000 - 6.000 ppm

Titanium cell:

Visual inspection to 
detect incrustations.

Summary of Contents for HIDROLIFE

Page 1: ...11 02 2020 REVIZE 11 02 2020 EN Salt electrolysis HIDROLIFE from 3g salt l Portable color display TFT Upgrade possible Worldwide remote control Self clean WIFI and MODBUS Sea water INSTALLATION AND USER GUIDE ...

Page 2: ...eatment system and a controller for swimming pools Water treatment The salt water electrolysis produces chlorine from a base of salt water of low salinity The electrolysis cell attains a production of sodium hypochlorite liquid chlorine from 3g salt per liter The chlorine combats and eliminates bacteria virus pathogenic agents and oxidizes organic matter present in the water The used sodium hypoch...

Page 3: ...ol water Let the circulation pump run during the first 24 hours The system may operate while the salt is dissolving and will operate without problems with salt concentrations from 2 5 g l to 50 g l In pools with strong insolation it s necessary to add 40 gr m3 of stabiliser isocyanuric acid General maintenance 1 The pool must be vacuumed as usual and the skimmers emptied whenever necessary 2 FILTE...

Page 4: ...cell is guaranteed for 5 000 hours approx 2 3 years of summer usage Free chlorine levels don t reach 0 8 ppm Increase filtration interval Increase electrolysis level Check levels of sodium bromide or common salt in the pool 6 gr NaCl l Check level of isocyanuric acid in pool 30 50 ppm only if using common salt Check if reactive agents in test kit are expired Check if the temperature or amount of u...

Page 5: ...m 1 to 24 hours Flow switch Gas sensor Hour counter Yes accessible by client Control production of disinfection g l Alarms Insufficient salt no flow pH metering pH extremely high or low pH max metering time memory error Display salt concentration Detects gr salt l precision 10 Production control by pool cover Programmable 0 100 production of disinfection depending on pool cover open or closed Prod...

Page 6: ...erometric Au Cu Glass Thermometer Measuring range 0 14 pH 0 1000 mV 0 10 ppm 0 20 000 MS 0 100 C Measuring precision 0 1 pH 1 3 mV 0 10 ppm 10 MS 100 MS 1 C Material Ag Cl Gold Copper gold Stainless steel Probe holder ABS 50 63mm Supplementary equipment Includes 2 m of flexible tube valve Cable 2 m Plug BNC with protection BNC with protection Connectors Connectors Connectors ...

Page 7: ...Salt electrolysis Hidrolife 7 Notes ...

Page 8: ...Thank you for using ALBIXON products ALBIXON export albixon com www ALBIXON com Note that the photos used in the manual are illustrative only Printing and typesetting errors reserved ...

Reviews: