The routing of the SHDSL cables should be in accordance with the recommended
practices of the cables selected. The cables should be strain relieved to prevent any force
from being exerted on the connectors.
ote:
The TU ports can be connected to the LTU ports in any order, as long as
newly connected ports are adjacent to the already used port (or group of ports) on the
LTU, and numerically incrementing port numbers on the TU are connected to
numerically incrementing port numbers on the LTU. Typical wiring errors are shown
in the “1645 AMC Alarm Messages and Trouble Clearing Guide”.
E3/DS3 interfaces (X3E3DS3 card)
Purpose
34368 kbit/s E3 and 44736 kbit/s DS3 inputs and outputs can be connected to these
interfaces.
Connector data
The E3/DS3 connectors which are located on the X3E3DS3 option card are DI 1.6/5.6
coaxial connectors (75 Ω, male).
Cable data
Preferably 75 Ω coax cables should be used (4.1 mm).
Cable connection
Please connect the E3 cables as shown in the figure below:
ote:
The routing of the E3 cables should be in accordance with the recommended
practices of the cables selected. The cables should be strain relieved to prevent any
force from being exerted on the connectors.
Connect the DS3 cables as shown in the figure below:
Figure 4-27 E3 cables
System cabling
Option card cable installation
SHDSL interfaces (X12SHDSL-V2 card)
...................................................................................................................................................................................................................................
...................................................................................................................................................................................................................................
365-313-103R8.0
Issue 2
July 2009
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
4-27