2
Change the default Alarm Reporting/Severity of the STM1cES (STM-1 ot Expected
Input Signal) alarm from reported “
No
” to “
Yes
”.
...................................................................................................................................................................................................
3
Provision the following cross-connections:
Result:
Port under test
Required cross-connections
TP2.1
TP2.1 – LP1.1,1
CC1,1.111 – TP1.1
CC1,1 – LP1.2,1
TP2.2
Change from TP2.1 – LP1.1,1 to TP2.2 –
LP1.1,1
TP2.3
Change from TP2.2 – LP1.1,1 to TP2.3 –
LP1.1,1
TP2.4
Change from TP2.3 – LP1.1,1 to TP2.4 –
LP1.1,1
TP2.5
Change from TP2.4 – LP1.1,1 to TP2.5 –
LP1.1,1
TP2.6
Change from TP2.5 – LP1.1,1 to TP2.6 –
LP1.1,1
...................................................................................................................................................................................................
4
Set the PDH analyzer to 2 Mbit/s, 2
15–1
PRBS pattern. Connect the analyzer to TP1.1.
...................................................................................................................................................................................................
5
Monitor the analyzer for correct transmission.
...................................................................................................................................................................................................
6
Display the raised alarm list on the ITM-CIT, and verify that the requirements mentioned
in the table below are met.
Result:
Requirements
LEDs on the 1645 AMC:
Power:
On
Fault:
Off
PDH analyzer:
o errors
Alarms reported on the ITM-CIT:
“STM1cES” (STM-1 ot Expected Input
Signal) on TP2.* (* is port under test)
Stand-alone test procedures
Optical X6STM1 option card test
...................................................................................................................................................................................................................................
...................................................................................................................................................................................................................................
7-16
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
365-313-103R8.0
Issue 2