13
Loop the in and out port of the GbE port with a fiber at the Optical Distribution Frame
(ODF). Use the correct type. Check the type of SFP (Single mode or multi mode).
...................................................................................................................................................................................................
14
Check on the alarm list, and verify that the requirements mentioned in the table below are
met.
Result:
Requirements
Link LED of related LA port:
On (green)
Alarms reported on the ITM-CIT:
“LAcES” reported on the related LA
...................................................................................................................................................................................................
15
Remove the loop fiber from the ODF.
Cleaning up
Reset the Alarm Reporting/Severity of the LAcES alarm type to default (ot
Reported).