Table 2-3
Available option cards
(continued)
Option card
Function
Comcode
X3E3DS3
Provides three E3/DS3 interfaces.
The option card provides three 34 Mbit/s or three 45 Mbit/s
interfaces to be used with the AMC main board.
The unit can be configured as either E3 or DS3 mode at one
time. Mixed configuration is not supported.
109642306
Environmental considerations
General
The 1645 AMC units must have room temperature and must be dry before they can be
taken into operation.
Environmental conditions
The environmental conditions for the 1645 AMC units are as follows:
•
Storage compliant with ETSI 300 019-1-1 Class 1-2, February 1992:
– Temperature range –5°C to +45°C
– Humidity of 5 to 95% without condensation
•
Transport compliant with ETSI 300 019-1-2 Class 2-3, February 1992:
– Temperature range –5°C to +45°C
– Humidity of 5 to 95% without condensation
•
The system operates with convection cooling.
•
CE marking compliant with 73/23/EEC and 89/336/EEC
Figure 2-5 Example of an option card
General information
Hardware description
...................................................................................................................................................................................................................................
...................................................................................................................................................................................................................................
2-8
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
365-313-103R8.0
Issue 2
July 2009