Local testing and operating sequence
Tests and Measurements
............................................................................................................................................................................................................................................................
PN 8DG08136CAAA
Issue 1 March 2008
3-9
............................................................................................................................................................................................................................................................
Local testing and operating sequence
Purpose
The purpose this section is to check the correct operating mode of the equipped units.
They are detailed in the following paragraphs.
Free-running frequency check
Purpose:
Verify the correct value of the frequency of the oscillator on the MATRIX.
Test instruments
Note:
See
Table 3-1, “Instruments” (p. 3-2)
.
•
Craft Terminal (E)
•
Frequency Counter (G)
Accessories
Note:
See
Table 3-2, “Accessories” (p. 3-2)
.
•
Cable for synchronization (P)
•
Craft Terminal cable (L)