Local testing and operating sequence
Tests and Measurements
............................................................................................................................................................................................................................................................
PN 8DG08136CAAA
Issue 1 March 2008
3-11
............................................................................................................................................................................................................................................................
Traceability Unknown,
” “
Stratum 2,
” “
Transit Node Clock,
” “
Stratum 3E,
” “
Stratum
3,
” “
SONET minimum clock,
” “
Stratum 4,
” “
Do Not Use,”
“
Failed state
” and “
Not
Assigned,
”
Sync Messaging
= “
Yes
” (Y) “
No
” (N) and
Revertive
= “
Yes
” (Y) “
No
” (N).
........................................................................................................................................................................................................................
3
Select “
Synchronization
” -> “
Modify Synchronization
Outgoing
”
•
Check that the “free-running” indication is present in the timing reference block
dedicated to the internal oscillator G.783. If the “Hold-Over” indication is displayed,
first switch the equipment off and then back on again. Afterwards repeat all the
procedures.
........................................................................................................................................................................................................................
4
Select “Synchronization” ->
“Modify Synchronization
Switch
”
•
Check that the frequency counter reads a measured value of 2048 kHz ±4.6 ppm. To
perform this measure, the “Squelch T0/T4” must be deactivated (green color), by
selecting Synchronization -> T4 Configuration; in “Squelch T0/T4” field, set T0 =
G.813
........................................................................................................................................................
E
N D
O
F
S
T E P S
TL1 Procedure
........................................................................................................................................................................................................................
1
Connect the outgoing synchronism to the frequency counter
•
Enter
ED-BITS-
OUT:[TID]::[CTAG]:::[,LINECDE=][,FMT=][,ESFTRANS=];
in order to verify that no reference has been selected for each Timing Reference block
except for the internal oscillator block “G.813.” Protocol G.813 local synchronization
level. To make the test set G.813 instead of G.811. Access the synchronization menu
and click on T4 modification, a T0 and T4 window will appear. Set G.813. On the
contrary remove all the timing reference source from each Timing Reference blocking
as follows:
Enter
ED-SYNCN-OUT /PRIOREFA / SECOREFA
Enter
OPR-SYNCNSW /SWITCHTO / CMDMODE
........................................................................................................................................................................................................................
2
Select the Timing Reference Block
........................................................................................................................................................................................................................
3
Select “Synchronization” -> “Remove Timing Reference”
Summary of Contents for 1850 TSS-320
Page 6: ... List of figures v i PN 8DG08136CAAA Issue 1 March 2008 ...
Page 8: ... List of tables v i i i PN 8DG08136CAAA Issue 1 March 2008 ...
Page 16: ... Safety rules Safety 1 4 PN 8DG08136CAAA Issue 1 March 2008 ...
Page 138: ... Other technical support services Technical Support A 14 PN 8DG08136CAAA Issue 1 March 2008 ...
Page 140: ... Glossary GL 2 PN 8DG08136CAAA Issue 1 March 2008 ...