Local testing and operating sequence
Tests and Measurements
3-20
PN 8DG08136CAAA
Issue 1 March 2008
............................................................................................................................................................................................................................................................
PTx power test
........................................................................................................................................................................................................................
1
Connect power meter to the optical port output being tested.
–
Check LOS alarm on Error Detector.
–
Check that the optical power is within the range stated on the table reported in
Chapter 4
,
“SFP and XFP modules optical characteristics” (p. 4-16)
.
........................................................................................................................................................................................................................
2
Switch off the LASER as specified in
Chapter 4
,
“Standard procedures to turn the laser
OFF then ON” (p. 4-14)
.
•
Program ALS Enabling port [see
Chapter 4
,
“Standard procedures to turn the laser
OFF then ON” (p. 4-14)
].
–
Check that the LASER power is null.
If the “ALS Automatic Restart” option is enabled, check if a power reset is
attempted after approximately 0 seconds. This condition must last approximately 2
seconds.
If these conditions do not occur, replace the optical unit under test.
–
Check if the Tx optical power is null.
•
Repeat the test on each optical unit.
•
Preset the instrument to transmit a signal (based on the type of port used) with the
following requirements:
........................................................................................................................................................
E
N D
O
F
S
T E P S
Data ports tests
GbE Transport on VC4-xV
Check GbE packets transport by means of VC4-xV (virtual concatenation)
Bit rate
155520 kbit/s
Code/interface (SFP)
S-1.1, L-1.1, L-1.2
[See
Chapter 4
,
“SFP and XFP modules
optical characteristics” (p. 4-16)
for
details.]
Type
OC-3 optical
Summary of Contents for 1850 TSS-320
Page 6: ... List of figures v i PN 8DG08136CAAA Issue 1 March 2008 ...
Page 8: ... List of tables v i i i PN 8DG08136CAAA Issue 1 March 2008 ...
Page 16: ... Safety rules Safety 1 4 PN 8DG08136CAAA Issue 1 March 2008 ...
Page 138: ... Other technical support services Technical Support A 14 PN 8DG08136CAAA Issue 1 March 2008 ...
Page 140: ... Glossary GL 2 PN 8DG08136CAAA Issue 1 March 2008 ...