Local testing and operating sequence
Tests and Measurements
3-32
PN 8DG08136CAAA
Issue 1 March 2008
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
5
Start transmitting at 10% of the available bandwidth
........................................................................................................................................................................................................................
6
Check that all the frames received are the same of those transmitted and no alarms are
detected by the instrument for 5 minutes.
........................................................................................................................................................................................................................
7
Alarms detection — Perform the cross-connection described above.
•
From EML-USM, select “Equipment” -> “Data board Navigation,” then insert login
and password. The Data CT starts.
–
In the “1850TSS User Service Management..” window, double click on the board
(i.e., r1sr1/board#2). The local and remote Data ports are displayed.
–
Select a local port. From the pop-up menu (click on the right button of the mouse),
select “Configure Ethernet port.”
–
In “Ethernet port Configuration” window, select “Configuration” tag and set “Up”
in “Admin. Status” field. Click on “OK.”
–
Select the port again. From the pop-up menu (click on the right button of the
mouse), select “Ethernet Port Properties.” Open the “Alarms” tag and check the
presence of the LOS alarm (red square).
•
Connect the Pattern Generator/Error Detector and check that the LOS alarm
disappears (green square) and that the on-board led related to the 10 GbE port under
test is green.
Pattern generator / Error Detector setup
Port type
GbE
Auto-negotiation
OFF
Frame length
1574 bytes
Bandwidth
10%
Optical interfaces (XFP) types
(refer to
Chapter 4
,
“SFP and XFP modules optical
characteristics” (p. 4-16)
for details)
10GbE XFP interface types (on
PIM10GE)
B&W = 10Gbase-E / 10Gbase-S / 10Gbase-L
DWDM = APD for long haul
Summary of Contents for 1850 TSS-320
Page 6: ... List of figures v i PN 8DG08136CAAA Issue 1 March 2008 ...
Page 8: ... List of tables v i i i PN 8DG08136CAAA Issue 1 March 2008 ...
Page 16: ... Safety rules Safety 1 4 PN 8DG08136CAAA Issue 1 March 2008 ...
Page 138: ... Other technical support services Technical Support A 14 PN 8DG08136CAAA Issue 1 March 2008 ...
Page 140: ... Glossary GL 2 PN 8DG08136CAAA Issue 1 March 2008 ...