background image

Alcatel-Lucent 

Last revised: 1 December 2009 

01RN0031_H0-30  

14)

 

ANS  

ANS-2 was added in Release 5.0 of the 3600 MainStreet Multiservice Bandwidth 
Managers. In Release 6.0, the creation of a new ANS-1 network was blocked. In 
Releases 6.0 and 6.1, ANS-1 is fully supported (topology configuration is allowed) if 
pre-6.0 nodes within an established ANS-1 network are upgraded to Release 6.0 and 
higher. Upgrade to ANS-2 could then take place. 

In Releases 7.x and later releases, ANS-1 is obsolete. ANS-1 topology configuration 
will be lost if nodes in an established ANS-1 network are upgraded to Release 7.x or 
later. ANS-1 must be upgraded to ANS-2 before the nodes are upgraded to Release 
7.x or later. 

15)

 

LS-DV router compatibility  

Router version 2 is also referred to as LS router. Router version 1 is referred to as DV 
router. 

No changes were made in Release 9.0 that affect LS-DV router compatibility that 
existed in Release 5.x loads. The implementation of the DV router in CPSSv2 is 
completely compatible with the previous implementation in CPSSv1. 

However, the LS router is only somewhat compatible with the DV router. All DV 
routing entities must be directly connected to LS routing entities. DV routing nodes 
that are not directly connected to an LS routing node will not be seen by any LS 
routers. 

16)

 

FRE and PE cards in 3600 MainStreet single, dual, and PU shelves 

Due to the extra power requirements of FRE and PE cards, it is recommended that 
double-harness (i.e., two-cable) power supply harnesses be used in 3600 MainStreet 
single, dual, and PU shelves containing these cards. As well, the FRE and PE cards 
should be placed in every second slot to maximize heat dissipation. 

17)

 

Limit of E3 circuits configured for OOS 

Due to the large processing requirement to perform A/B switches in 3600 MainStreet 
multishelf systems, the maximum number of circuits that should be configured for 
OOS detection is 375 (approximately 12 E1s configured for CCS). If this limit is 
exceeded, the SE3/DE3 peripheral may go out of service if all circuits detect OOS 
simultaneously. 

18)

 

1.544 Mb/s SU composite clock external synch source 

Support for 3600 MainStreet multishelf SU 1.544 Mb/s composite clock external sync 
source requires minimum ISSU F/W ID of $2.  

19)

 

4WTO interface 

Tx/Rx on the interfaces of the 4WTO card are as defined in Bellcore specification 
TR-NWT-000057, not as they are on the 4WT0 module on the 3624 MainStreet unit. 

Page 10 

Summary of Contents for 3600 MainStreet

Page 1: ...Alcatel Lucent Last revised 1 Dec 2009 01RN0031_H0 30 3600 and 3600 MainStreet Release Notice Release 9 0 Load x119 H0 30...

Page 2: ...ries and or other related entities No part of its contents may be used copied disclosed or conveyed to any party in any manner whatsoever without prior written permission from Alcatel Lucent Copyright...

Page 3: ...d problems 5 3 1 Fixed problems for 3600 and 3600 MainStreet systems 5 Critical problems 5 Major problems 5 Minor problems 5 3 2 Fixed problems for 3600 MainStreet multishelf systems 6 3 3 Fixed probl...

Page 4: ...roduced the additional functionality listed below and specified in 01RD0023 GSLC 12 and GSLC 16 line cards these cards provide the same functionality as the 28LC line card but use G SHDSL technology i...

Page 5: ...H0 26 PTS fixes H0 30 PTS fixes 3 Fixed problems These problems are fixed in load H0 30 and are organized by priority and PTS number 3 1 Fixed problems for 3600 and 3600 MainStreet systems Critical p...

Page 6: ...te properly When using Octal E1 or Octal T1 card redundancy on the 3600 MainStreet node ensure that the paired slots are adjacent to each other with the first card in the lower numbered slot for examp...

Page 7: ...ut also apply to previous releases of the 3600 and 3600 MainStreet software 1 Dual E3 Dual E3 2 pair If a 3600 MainStreet multishelf system containing a Dual E3 and Dual E3 2 pair is upgraded from Rel...

Page 8: ...with Memory module DMM2 Release 9 0 cannot be installed on any version of Control card 2 or on a Control card 3 with Memory module II 8 3600 MainStreet Control card and MEM2 Release 9 0 requires that...

Page 9: ...ager after the node has been upgraded to Release 9 0 from any previous node release for which conversion is supported 12 Reset of DSP cards after upgrade To cover the instances where DSP cards must be...

Page 10: ...outer All DV routing entities must be directly connected to LS routing entities DV routing nodes that are not directly connected to an LS routing node will not be seen by any LS routers 16 FRE and PE...

Page 11: ...o Release 7 x to provide enhanced communication with the packet based UCS cards New releases of the packet based card firmware are required to obtain this new functionality Older releases of the card...

Page 12: ...er 2009 01RN0031_H0 30 Page 12 5 Release load history Load Date created H0 00 9 June 2004 H0 10 23 August 2005 H0 10 S1119 18 May 2006 H0 15 30 June 2006 H0 21 7 December 2007 H0 25 17 June 2008 H0 26...

Reviews: