01RN0031_H0-30 

20)

 

FRS/FRE cards 

FRS/FRE card circuits should not be used to terminate CPSS due to performance 
reasons. DCP cards should be used for this purpose.  

21)

 

Telco Alarm module  

The Telco Alarm module (Alarm module 2) now supports the audible alarm indicators 
for standard alarming in Release 7.x and later releases. The minimum variant ID for 
the Telco Alarm module is now $5 (80-1282-01-01). With the older variant, audible 
alarm indicators will not function. 

22)

 

Enhanced packet communication fault handling  

A new feature was added to Release 7.x to provide enhanced communication with the 
packet-based UCS cards. New releases of the packet-based card firmware are required 
to obtain this new functionality. Older releases of the card firmware will still work in 
Release 7.x and later releases, but only with the same functionality that they had in the 
older releases. 

The minimum firmware required for the enhanced packet communication fault 
handling is: 

 FRE 

card: 

 

P413-F0-00, 

PA12-F0-00 

  X.25 FRE card:  

P612-F0-00 

 PE 

card: 

 

P611-F0-00 

23)

 

Number of CPCs in a 3600 MainStreet single, dual, or PU shelf 

It is recommended that no more than one CPC be installed in a 3600 MainStreet 
single, dual, or PU shelf. An acceptable alternative is two CPCs with at least half the 
total circuits set to Interface Type = NONE.  

 

Page 11 

Summary of Contents for 3600 MainStreet

Page 1: ...Alcatel Lucent Last revised 1 Dec 2009 01RN0031_H0 30 3600 and 3600 MainStreet Release Notice Release 9 0 Load x119 H0 30...

Page 2: ...ries and or other related entities No part of its contents may be used copied disclosed or conveyed to any party in any manner whatsoever without prior written permission from Alcatel Lucent Copyright...

Page 3: ...d problems 5 3 1 Fixed problems for 3600 and 3600 MainStreet systems 5 Critical problems 5 Major problems 5 Minor problems 5 3 2 Fixed problems for 3600 MainStreet multishelf systems 6 3 3 Fixed probl...

Page 4: ...roduced the additional functionality listed below and specified in 01RD0023 GSLC 12 and GSLC 16 line cards these cards provide the same functionality as the 28LC line card but use G SHDSL technology i...

Page 5: ...H0 26 PTS fixes H0 30 PTS fixes 3 Fixed problems These problems are fixed in load H0 30 and are organized by priority and PTS number 3 1 Fixed problems for 3600 and 3600 MainStreet systems Critical p...

Page 6: ...te properly When using Octal E1 or Octal T1 card redundancy on the 3600 MainStreet node ensure that the paired slots are adjacent to each other with the first card in the lower numbered slot for examp...

Page 7: ...ut also apply to previous releases of the 3600 and 3600 MainStreet software 1 Dual E3 Dual E3 2 pair If a 3600 MainStreet multishelf system containing a Dual E3 and Dual E3 2 pair is upgraded from Rel...

Page 8: ...with Memory module DMM2 Release 9 0 cannot be installed on any version of Control card 2 or on a Control card 3 with Memory module II 8 3600 MainStreet Control card and MEM2 Release 9 0 requires that...

Page 9: ...ager after the node has been upgraded to Release 9 0 from any previous node release for which conversion is supported 12 Reset of DSP cards after upgrade To cover the instances where DSP cards must be...

Page 10: ...outer All DV routing entities must be directly connected to LS routing entities DV routing nodes that are not directly connected to an LS routing node will not be seen by any LS routers 16 FRE and PE...

Page 11: ...o Release 7 x to provide enhanced communication with the packet based UCS cards New releases of the packet based card firmware are required to obtain this new functionality Older releases of the card...

Page 12: ...er 2009 01RN0031_H0 30 Page 12 5 Release load history Load Date created H0 00 9 June 2004 H0 10 23 August 2005 H0 10 S1119 18 May 2006 H0 15 30 June 2006 H0 21 7 December 2007 H0 25 17 June 2008 H0 26...

Reviews: