Automatic protection switching and alarm test
Operational tests
5 - 1 0
365-372-304R7.1
Issue 1, November 2007
........................................................................................................................................................................................................................
7
Select View -> Protection.
........................................................................................................................................................................................................................
8
Under Path Protection choose m-1-1.
........................................................................................................................................................................................................................
9
Click Select.
........................................................................................................................................................................................................................
10
Note the Active Path: (m1-1-1 or m2-1-1).
The M1 OLIU is associated with Ring 1 and the M2 OLIU is associated with Ring 2.
........................................................................................................................................................................................................................
11
Disconnect the optical fiber connected to the
IN
port of the OLIU that is the active
receiver.
Result:
The MN and then NE alarm LED should light on the SYSCTL and the FAULT
LED should flash on the OLIU.
........................................................................................................................................................................................................................
12
Click Refresh in the View Protection window.
Result:
The Active path has changed. (If m1-1-1 was active before, m2-1-1 is active
now).
........................................................................................................................................................................................................................
13
Reconnect the fiber at the OLIU.
Result:
After a short time, the MN and NE alarm LEDs on the SYSCTL and the
FAULT LED on the OLIU should extinguish.
........................................................................................................................................................................................................................
14
to verify a switch back to the OLIU that was originally
active.
........................................................................................................................................................................................................................
15
Check off the appropriate box in
Appendix E, “Installation checklist”
.
........................................................................................................................................................
E
N D
O
F
S
T E P S
Summary of Contents for Data Multiplexer Explore 1665
Page 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Page 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Page 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Page 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Page 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...