Choosing a suitable location

The OmniAccess 5305 BG must be installed within 2 metres of a dedicated mains
power outlet.

Do not place the unit close to a heat source (such as other electrical equipment) or
in direct sunlight.

Avoid locations exposed to heavy soiling due to exhaust from machinery, airborne
particles from industrial processes or excessive dust.

Do not enclose the device within an unventilated housing where heat may
accumulate.

2

Connecting the telephone service

Your telecommunications equipment can be plugged into the 

Voice 

ports either

directly or via a suitable converter. This depends on the OmniAccess 5305 BG
model and the type of equipment on your premises. 

2.1      Where a product has a BRI Port , this will be configured in NT mode, and as

such is classified as SELV (Safe Extra Low Voltage). This port must not be
connected to a TNV (Telecom Network Voltage) network. For example the
BRI port must not be connected to a port with wiring that is either directly or
indirectly external to the building.

2.2

The BRI ports must not connected to another NT mode port, this includes
other ISDN network terminating equipment (ISDN lines delivered by other
providers). The action of connecting an NT configured port to an NT port may 
cause damage to both pieces of equipment.

OmniAccess 5305 BG Series User's Guide

7

VENTILATION HOLES

Important!

To ensure adequate
airflow through the unit, 
please ensure that the
ventilation holes are
unobstructed at all
times.

Summary of Contents for OmniAccess 5305 BG

Page 1: ...OmniAccess 5305 BG Business Gateway User s Guide...

Page 2: ...ine into any port other than the ADSL port as this may damage the product If the OmniAccess 5305 BG needs to be relocated disconnect all telecommunications lines before switching off There are no user...

Page 3: ...r you Your Telephone Service The OmniAccess 5305 BG is fitted with one or more of the following port options or a combination to support your telephone requirements POTS Plain Old Telephony System por...

Page 4: ...cess The OmniAccess 5305 is fitted with 4 Ethernet ports Depending on product type the OmniAccess 5305 BG may also be enabled for wireless connectivity Mains Operation The OmniAccess 5305 BG is mains...

Page 5: ...s following an interruption in the power supply and after a break in the DSL service The unit establishes the link in two stages synchronizing to the network training to the network Flashing in sync w...

Page 6: ...mniAccess 5305 BG by a qualified service engineer only Unauthorised use of this port may damage the product and invalidate your warranty LAN for connection either to a single PC or to your Local Area...

Page 7: ...ed with LED s LED State Meaning LINK On LAN connection established LINK Off No LAN connection established LINK Flashing Data activity on LAN port 100 On 100 BaseT connection 100 Off 10 BaseT connectio...

Page 8: ...may be provided for use with the OmniAccess 5305 BG an Ethernet cable a DSL interface cable converters for the different types of telephone equipment that you have on your premises additional installa...

Page 9: ...n the OmniAccess 5305 BG model and the type of equipment on your premises 2 1 Where a product has a BRI Port this will be configured in NT mode and as such is classified as SELV Safe Extra Low Voltage...

Page 10: ...mage the unit and may invalidate its warranty and approval 5 2 If necessary switch power on at the mains socket 6 Checking that the OmniAccess 5305 BG is operational 6 1 Observe the LEDs as the OmniAc...

Page 11: ...rgency services during a power failure or failure of the DSL service In the event of a power failure where a product is fitted with POTs port 2 links through to the DSL In this situation a series micr...

Page 12: ...following sections Power Problem Examine the Power LED Power LED status Action to be taken On steady Go on to investigate a possible DSL Line Problem Flashing Please make a note of which other LED is...

Page 13: ...Check the cable connections between the OmniAccess 5305 BG and your telecommunications equipment If all cables are secure proceed as follows Where telephones are plugged directly into the OmniAccess...

Page 14: ...f you still have no service please contact your service provider LAN Problem Examine the LAN LED LAN LED status Action to be taken On Check the integrity of your network If you still have no service p...

Page 15: ......

Page 16: ...on relates is compliant with the essential requirements of R TTE Directive 1999 5 EC of 9 March 1999 RoHS Directive 2002 95 EC of 27 January 2003 WEEE Directive 2002 96 EC of 27 January 2003 Energy Us...

Reviews: