Performing Maintenance
Removing Modules from the Chassis
50
255-700-161
PacketStar
®
PSAX 2300 Multiservice Media Gateway Installation Guide
, Issue 4
4
If another module is not being immediately inserted into the empty slot, insert a
blank faceplate module into the slot to maintain optimum EMI shielding and
proper ventilation for the chassis.
!
CAUTION:
Ultimate disposal of this product should be handled according to all laws and
regulations in your specific geographic region.
End
Removing the Alarm Module
Perform the following procedure to remove the Alarm module.
Read the
PacketStar
®
PSAX Multiservice Media Gateway Safety Guidelines
, which
accompanies this product, before proceeding.
Begin
1
Disconnect the cables from the two connectors.
2
For modules that have the locking tab at the bottom of the faceplate, insert a flat-
head screwdriver into the screwdriver slot, and slide the locking tab up and out of
the locking tab slot (see Figure 23).
3
Pull backward on the ejector handle until the module is pulled out of the slot.
4
Place the module in ESD packaging and close it.
5
If a replacement module is not being immediately inserted into the empty slot,
insert a blank panel into the slot to prevent EMI and maintain proper air flow
inside the chassis.
Figure 23. Locking Tab on the Alarm Module Faceplate
4