Performing Maintenance
Removing Modules from the Chassis
46
255-700-161
PacketStar
®
PSAX 2300 Multiservice Media Gateway Installation Guide
, Issue 4
Removing Modules from the Chassis
The modules installed in the PSAX 2300 system can be replaced, or “hot swapped”,
while the power is applied and without disrupting service on the other modules in the
system. These procedures assume redundant common equipment modules are
installed.
Note:
If a replacement module is not being immediately inserted into the empty
slot, insert a blank faceplate module into the slot to maintain optimum
EMI shielding and proper ventilation for the chassis. Ordering information
on the blank faceplate modules can be found in Appendix B.
WARNING:
!
Blank faceplates must be installed in empty slots to minimize EMI and maintain
proper air flow through the chassis.
Removing a DC Power Supply Module
Perform the following procedure to remove the -48 V dc Power Supply module from
the chassis.
Begin
Read the
PacketStar
®
PSAX Multiservice Media Gateway Safety Guidelines
, which
accompanies this product, before proceeding.
WARNING:
!
Remove only one Power Supply module at a time in a live network.
1
Using a flathead screwdriver, loosen the two captive screws on both sides of the
Power Supply module.
2
With steady backward pressure, pull the module straight out of the chassis.
3
Put the module in ESD packaging and close it.
!
CAUTION:
Ultimate disposal of this product should be handled according to all laws and
regulations in your specific geographic region.
End
Removing the Stratum 3–4 Module
Perform the following procedure to remove a Stratum 3–4 module.