57/314
3CC08991ATAA TQ BJA 01
Issue 01 -- March 2004
ELECTROMAGNETIC COMPATIBILITY / SAFETY
EMC
EN 301 489 1 & 4 (version 1.2.1)
Safety
EN 60 950
Power supply
EN 300 132
Lightning protection
Symmetric protection implemented in ODU & IDU
+/-- 1kV on cable ground according to IEC 61000--4--5 with 2 wave types:
1.2/50
←
s and 10/700
←
s
IDU--ODU CABLE
Type
1AC001100022
Fire resistance
IEC 332--1
Max distance
300 m
ENVIRONMENTAL CONDITIONS
Storage
EN 300 019 class 1.3
Transport
EN 300 019 class 2.3
IDU
EN 300 019 class 3.2
Temperature range : --10 to +55
C
Operation
ODU
EN 300 019 class 4.1,
Protection factor IP 55 (IEC529 standard)
Temperature range : --33 to +55
C
MECHANICAL
Classic Main IDU,
Extension IDU, Access IDU
44x450x235 mm / 3 kg (19” / 1U)
Light IDU
44x450x235 mm / 3 kg (19” / 1U)
ODU
94
XX
UXR201
13 to 18
GHz
250x250x250 mm / 10kg
94
XX
UXR201
94
XX
UXR202
94
XX
UXR203
23 to 38
GHz
220x220x250 mm / 8 kg
ODU
A9400UX flat
ODU
13 to 38
GHz
235x235x72 mm / 4 kg
For the typical installation dimensions, see Chapter 3
Summary of Contents for 9400 UX
Page 1: ...3CC08991ATAA TQBJA 01 Alcatel 9400 UX User Manual ...
Page 4: ...4 314 3CC08991ATAA TQ BJA 01 Issue 01 March 2004 PAGE INTENTIONALLY LEFT BLANK ...
Page 6: ...6 314 3CC08991ATAA TQ BJA 01 Issue 01 March 2004 PAGE INTENTIONALLY LEFT BLANK ...
Page 14: ...14 314 3CC08991ATAA TQ BJA 01 Issue 01 March 2004 PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ...19 314 3CC08991ATAA TQ BJA 01 Issue 01 March 2004 1 3 5 Eco Declaration ...