92/314
3CC08991ATAA TQ BJA 01
Issue 01 -- March 2004
3.6
--
Wiring
3.6.1 -- Wiring the power supply to the 19” indoor units
3.6.1.1 -- Direct connection with the power supply
The 48 V DC or 24 V DC connection kit is for setting up the power connection between the main or extension
IDU and the distribution panel (one for each terminal). On the user side, the plus or minus pole can be
grounded in the current version of the equipment.
Preparing the connecting cable
--V female contact
+V female contact
Ground
For 48 V supply, 3 x 1.5 mm
2
connecting cable
(minimum), flexible, unshielded
For 24 V supply, 3 x 2.5 mm
2
connecting cable
(minimum) flexible, unshielded
Plug + shell reference: 3CC08048AAxx or ABxx
(supplied with the connector kit)
Shell
3.6.1.2 -- Power panel and IDU
19”, 3U internal power panel (ref: 9400XXC511)
This provides six ways protected by 6A fuses, providing remote connection to the “operator’s” power input.
Wall mounted power unit (ref: 9400XXC512)
This provides six ways protected by 6A fuses, for
remote connection to the “operator’s” power input.