31 — Hardware maintenance procedures
31-4
2902 MainStreet Technical Practices
90-2906-01 May
2002
Procedure 31-1 To remove and check the fuse
1
Turn off the power switch.
2
Disconnect the power cord by unplugging it from the ac source, and then from the
unit.
3
With a small blade screwdriver, pry the fuse holder away from the power connection
module and pull the fuse holder out (see Figure 31-3).
Figure 31-3 Removing the fuse holder
4
Remove the fuse and test it for continuity.
If it passes the test, put the fuse back in the fuse holder. If it fails the test, install a
new fuse. A spare fuse may be kept in the spare fuse compartment (see
Figure 31-4).
Figure 31-4 Spare fuse compartment
5
Put the fuse holder back in the power connection module.
6
Turn on the power switch.
See section 4.4 in
Installation
for a description of startup diagnostics.
8958
Fuse
Fuse
holder
Spare fuse
compartment
8959
Summary of Contents for MainStreet 2902
Page 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Page 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 343: ......
Page 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...