5 — Installing and removing modules
2902 MainStreet Technical Practices
5-3
May 2002 90-2906-01
Figure 5-2 Opening the unit
5.3
Installing and removing primary rate modules
Each primary rate module has a female connector that fits onto a male connector on
the Control card. The modules are secured to mounting posts on the Control card
with screws. The holes in the module should line up with the posts. If they do not,
you are installing the module in the wrong location.
There are two jumper blocks for each primary rate module on the Control card. The
jumpers need to be configured for E1 G.703 and E1 HDSL LIMs. The jumper
configurations do not affect operations for other primary rate modules.
Procedure 5-2 To install E1 G.703 or E1 HDSL LIMs
You need a #2 Phillips screwdriver to install E1 G.703 or E1 HDSL LIMs.
1
Ensure that the unit is turned off and that the power cord is unplugged.
2
Open the unit.
3
Remove the screws from the appropriate Control card mounting posts.
4
Locate the jumper blocks on the Control card corresponding to the module position.
Jumper blocks J37 and J40 correspond to LIM P1; jumper blocks J41 and J44
correspond to LIM P2 (see Figure 5-3).
8975
Line-1
Slot 2
Slot 1
Line-2
Modem
Terminal
Rx-1
Tx-1
Rx-2
P1
P2
Tx-2
Alarm
Loop
Displa
y
Status
2
1
U
O
I
EDG
Sig/Gnd
Warning 1 —
Ensure that the power is off before inserting or
removing primary rate modules.
Warning 2 —
Electronic circuitry is easily damaged by electrostatic
discharge. Wear a properly attached antistatic wrist strap before
handling any electronic component. Handle modules by their edges.
Summary of Contents for MainStreet 2902
Page 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Page 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 343: ......
Page 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...