Open Problem Reports and Feature Exceptions
OmniSwitch 6800/6850/9000—Release 6.1.3.R01
page 49
PR 106811
Show interface slot/port "SFP/XFP" field output for a port having SFP plugged in cannot differentiate
between 100Fx and Bidirectional SFP & between Gig and CWDM SFP on an OS6850.
Workaround:
There is no known workaround at this time.
RMON
Problem Reports
PR 87683
On an OS6800/OS9000, the RMON object etherStatsPkts65to127Octs and other similar objects from RFC
1757 contain TX and RX packet counts.
Workaround:
There is no known workaround at this time.
PR 106919
On an OS6850, it is not possible to disable all RMON probes with a single SNMP command.
Workaround:
When using SNMP, disable each probe individually.
sFlow
Problem Reports
PR 100009
On an OS6850, sFlowCpTable and sFlowFsTable return data of zero when an existing NI is removed or
powered down.
Workaround:
There is no known workaround at this time.
PR 106130
The syntax for sflowReceiver and sFlowAgent returned by an OS9000 are not octets, but strings.
Workaround:
There is no known workaround at this time.
PR 106878
When replacing an NI with a different type of NI, the sFlow configuration is not deleted correctly for the
ports which do not exist anymore.
Workaround:
Delete the sFlow configuration before swapping different NI types.