Temporis IP80 User’s guide
V1.0
Page 19
4.13.
Service
1
: Shows current firmware version
2:
Shows the different logs:
Download event log (All logs)
Show call log (incoming and outgoing call log)
Show register log (all the logs related to SIP registration)
Show VoIP log (All VoIP traces)
3
: NTP server and time zone
4
: External Syslog server
5
: Firmware upgrade: click on “browse”, select the firmware file then press “save”.
6
: Language upgrade
7
: Save current configuration in a file.
8
: Upload a configuration file
9:
Change the admin password
5.
Electrical Parameters
Parameter
Value
Conditions
Communication interface
Ethernet 10Base-T, 100Base-TX
VoIP protocol supported
SIP
Bandwidth
300Hz – 3400Hz
Power supply
12V ± 2V AC or DC
Max. consumption
300mA
12Vss
Max. voltage of switch contact
48V
at I < 1A
Max. current of switch contact
2A
at U < 30 V
Operational temperature
- 20 to + 50°C
1
2
3
4
5
6
7
8
9