21
EN
EasyHOME
®
HYGRO COMPACT Premium MW & HP
Supplier brand
Aldes
Aldes
Designation
EasyHOME
®
HYGRO COMPACT
Premium MW
EasyHOME
®
HYGRO COMPACT
Premium HP
References
11033050 - 11033051
11033052 - 11033054
Energy class - Average climate
B
B
Average climate - SEC - Specific energy consumption (kWh/(m
2
a year)
-27,13
-26,47
Cold climate - SEC - Specific energy consumption (kWh/(m
2
a year)
-54,20
-53,53
Warm climate - SEC - Specific energy consumption (kWh/(m
2
a year)
-11,63
-10,96
Type of airflow
SF
SF
Declared type
UVR
UVR
Type of motor installed or planned
4/ Variable speed
4/ Variable speed
Type of heat recovery system
N/A
N/A
Thermal efficiency of heat recovery (%)
N/A
N/A
Maximum RVU (m
3
/h)
248
325
Electric power absorbed at Qmax (W)
21,2
37,1
LwA - Sound power level (dB)
42
44
Reference airflow (m
3
/s)
0,050
0,060
Difference in reference pressure (Pa)
123
125
SPI (W/(m
3
/h)
0,09
0,1
Control factor (%)
0,65
0,65
Type of control system
Local Demand Control
Local Demand Control
Maximum declared internal leakage rate under negative pressure
for BVU (%)
N/A
N/A
Maximum declared external leakage rate under negative pressure
for UVU and BVU (%)
0,7
0,5
Maximum declared internal leakage rate under positive pressure
for BVU (%)
N/A
N/A
Maximum declared external leakage rate under positive pressure
for UVU and BVU (%)
N/A
N/A
Mixing rate for standalone BVU without branch connections (%)
N/A
N/A
Position of visual alarm
N/A
N/A
Description of visual alarm
N/A
N/A
Regular replacement of filters to ensure unit performance and energy
efficiency
N/A
N/A
Instructions for installation of fresh air inlets
Cf. Notice
Cf. Notice
Sensitivity of airflow to pressure variations at +20 Pa
N/A
N/A
Sensitivity of airflow to pressure variations at -20 Pa
N/A
N/A
Indoor/outdoor air tightness (m
3
/h)
N/A
N/A
Annual electricity consumption (kWh electricity/a year)
47
73
Average climate - AHS - Annual heating savings
(kWh primary energy/a year)
2830
2830
Cold climate - AHS - Annual heating savings (kWh primary energy/a year)
5536
5536
Warm climate - AHS - Annual heating savings (kWh primary energy/a year)
1280
1280