background image

Page 5 | RDF Installation Supplement

©2020 American ALDES Ventilation Corporation and ©2020 ALDES Canada. RDF_InstallationSupplement_IOM_1020. Aldes reserves the right to modify its products at any time to introduce new technologies.

 

For more information, contact your Aldes sales advisor, visit aldes-na.com, call 1.800.255.7749, or find us on

3  Year  Warranty:  This  Warranty  Supersedes  All  Prior  Warranties                                               

DURING THE FIRST 30 DAYS:

ALDES will repair or replace any product 

that has a factory defect in workmanship 

or material. Product(s) may be returned to 

point of purchase or the ALDES factory, 

with Bill of Sale, for an immediate 

replacement. 

DURING THE FIRST 3 YEARS:

(Excluding the 30-day period above)

ALDES will repair or replace any product 

that has a factory defect in workmanship 

or material. Product(s) must be returned 

to the ALDES factory, with Bill of Sale and 

identified with an RMA number, within 3 

years of purchase. The warrantee assumes 

all costs to and from the factory.

WARRANTY DOES NOT APPLY TO THE 

FOLLOWING:

1.  Damages from shipping, either 

concealed or visible. Claim must be 

filed with the carrier.

2.  Damages resulting from improper 

wiring or installation.

3.  Damages or failure caused by Acts 

of God, or resulting from improper 

consumer procedures, such as:

-Improper maintenance

-Misuse, abuse, abnormal use, or 

accident

-Incorrect electrical voltage or 

current

-Removal or alterations made on 

the ALDES label, control number, 

or date of manufacture.

4.  Any other warranty, expressed, 

written, or implied, and to any 

consequential or incidental damages, 

loss of property, revenues, or profit, 

or costs of removal, installation, 

or reinstallation, for any breach of 

warranty.

WARRANTY VALIDATION

The end user must keep a copy of the 

Bill of Sale to verify purchase date. Valid 

proof of the date of installation may also 

serve as a verification of commencement 

of warranty period.

ALDES RETURN POLICY

Claims for damages or order shortages 

must be reported within 10 days of receipt 

of product(s). For any product(s) received 

damaged by the forwarding agent, the 

following instructions MUST BE followed:

1.  For product(s) delivered by UPS:

-Concealed Damages: Keep all 

cartons; call UPS for an inspection 

and notify ALDES immediately.

-Visible Damages: Save all cartons 

and file a complaint directly with 

UPS.

2.  For product(s) delivered by Common 

Carrier: File damaged goods claim 

directly with the freight company.

3.  Shortages: Only sign for the total 

number of pieces received and 

contact ALDES immediately.

FOR FACTORY RETURN

ALDES WILL NOT ACCEPT THE RETURN OF 

ANY SPECIAL, NON-STOCK, OBSOLETE, OR 

UNSALABLE PRODUCT(S). ALDES MAY, 

AT ITS DISCRETION, ACCEPT RETURN OF 

SALABLE PRODUCT(S) SUBJECT TO A 25% 

RESTOCKING CHARGE.

1.  No product(s) will be accepted 

w i t h o u t   a   R e t u r n   M ate r i a l s 

Authorization (RMA) number. RMA 

number can be obtained by calling 

ALDES at 1-800-255-7749. Have 

the Bill of Sale or proof of date of 

installation available.

2.  RMA must be clearly marked on 

outside of carton or delivery will 

be refused. All product(s) must be 

returned freight prepaid.

3.  Product(s) will be repaired/replaced 

and shipped back to buyer; no credits 

will be issued.

4.  Any out-of-warranty product will be 

evaluated and buyer will be notified 

of cost. Repair cost will be charged to 

customer. Buyer will be responsible 

for return freight, or product may 

be returned to the buyer, freight 

collect, without action. No credit 

will be issued.

LIMITATIONS OF WARRANTY AND 

LIABILITY

This warranty does not apply to any ALDES 

product or part which has failed as a result 

of faulty installation or abuse, incorrect 

electrical connections or alterations 

made by others, use under abnormal 

operating conditions, or misapplication 

of the product or parts. ALDES will not 

approve for payment any repair not made 

by us or our authorized agent without 

prior written consent. The foregoing shall 

constitute our sole and exclusive warranty 

and our sole exclusive liability, and is in 

lieu of any other warranties, whether 

written, oral, implied, or statuary. There 

are no warranties that extend beyond 

the description herein. In no event, 

whether as a result of breach of contract 

or warranty, or alleged negligence, 

defect, incorrect advice or other causes, 

shall ALDES be liable for special or 

consequential damages, including but 

not limited to, loss of profits or revenue, 

loss of use of equipment or any other 

associated equipment, cost of capital, 

cost of substitute equipment, facilities 

or services, downtime costs, or claims of 

customers of purchases for such damages. 

ALDES neither assumes nor authorizes 

any person to assume for it any other 

liability in connection with the sale of 

product(s) or part(s). Some jurisdictions 

do not allow the exclusion or limitation 

of incidental or consequential damages, 

so the above limitations and exclusions 

may not apply to you.

WARNING

ALDES products are designed and 

manufactured to provide reliable 

performance, but they are not guaranteed 

to be 100% free of defects. Even reliable 

products will experience occasional 

failures and this possibility should be 

recognized by the user. If these products 

are used in a life-support ventilation 

system where failure could result in loss or 

injury, the user should provide adequate 

back-up ventilation, supplementary 

natural ventilation, a failure alarm system, 

or willingly acknowledge the risk of such 

loss or injury.

Summary of Contents for Ventergy IAQ-FSVS

Page 1: ...e superior solution for better indoor air quality comfort and energy efficiency VENTERGY IAQ FSVS RESIDENTIAL SYSTEM SOLUTIONS FILTERING SUPPLY VENTILATOR ACCESSORY KITS CONTINUOUS SUPPLY 2020 American ALDES Ventilation Corporation VentergySeries_IAQ FSVS_KIT_IOM_1020 Aldes reserves the right to modify its products at any time to introduce new technologies For more information contact your Aldes s...

Page 2: ...016309 Ø 5 125 mm 10 50 CFM 15 85 m3 h m3 h CFM m3 h CFM L 15 9 I 25 15 G 60 35 F 30 18 65 38 D 70 41 C 75 44 B 45 26 80 47 A 50 29 85 50 P N 11016311 Ø 6 150 mm m3 h CFM R 100 60 P 110 65 O 120 70 M 130 75 L 140 80 K 150 90 J 160 95 m3 h CFM H 170 100 G 180 105 F 190 110 E 200 120 D 210 125 A 240 140 Certain letters correspond to two setpoints one with the clip and one without the clip 11016307 Ø...

Page 3: ...uce new technologies For more information contact your Aldes sales advisor visit aldes na com call 1 800 255 7749 or find us on MR Modulo performance is not altered by clogging therefore it requires practically no special maintenance If the intended application includes air heavily loaded with grease or dust a fitting with an access panel or door such as that used for flame dampers should be used ...

Page 4: ...ssories such as knob dial plate mounting hardware instructions and individual carton All models are designed to be mounted into a standard 2 x 4 electrical wall box VARIABLE SPEED CONTROL FAN CONTROLS ISO 9001 2000 QMS 5 10 15 AMP CURRENT RATINGS SPEC IOM READ AND SAVE THESE INSTRUCTIONS 1 Models rated 10 A and above include mounting kit ELECTRICAL RATINGS AND AGENCY APPROVALS Part Number AC Line ...

Page 5: ...Temperature Test The non sinusoidal output voltage of a solid state speed control may increase motor heating Therefore it is necessary that a temperature test be performed to ensure that the motor is operating within manufacturer s specifications 5 Leads All leads are approximately 6 15 cm long and stripped 1 2 1 25 cm SAFETY WARNING Unit should be installed by a qualified electrician in accordanc...

Page 6: ...hen backdraft dampers are not present at other locations within the duct system Dimensions HIGH PERFORMANCE WALL HOODS ROOF CAPS WALL HOODS GRILLES DUCT FITTINGS WITH SCREENS OR GRAVITY DAMPERS 2020 American ALDES Ventilation Corporation and 2020 ALDES Canada HP_WallHoods_SPEC_0920 Aldes reserves the right to modify its products at any time to introduce new technologies For more information contac...

Page 7: ...For continuous operation the fan should be installed separately from the forced AHU to prevent moisture in the air from condensing inside cold ducts or cold air coming in contact with the heat exchanger The fan may be ducted so that fresh air is introduced into a living area via an overhead return FSVS140 VENTERGY SERIES FANS WARRANTY 3 YEARS FILTERING SUPPLY AIR VENTILATORS Fan and Motor The fan ...

Page 8: ...cy motor meets ENERGY STAR performance criteria Internally insulated with acoustic vapor barrier insulation REFERENCE RDF INSTALLATION SUPPLEMENT FOR ADDITIONAL INSTRUCTIONS AND WARRANTY INFORMATION Ducting the Fan Theductingfromthisfantotheoutsideofthebuildinghasastrongeffect ontheairflow noiseandenergyuseofthefan Usetheshortest straightest duct routing possible for best performance and avoid ins...

Page 9: ...CHEMATIC RUBBER FEET L Bracket secured to Building framing or concrete anchor FILTER ACCESS DOOR MOTOR ACCESS DOOR L Bracket secured to Wall framing or concrete wall with anchors GROMMETS FILTER ACCESS DOOR MOTOR ACCESS DOOR Suspension with threaded rods or cable through grommets in L Bracket Sold separately Refer to IOM text for details SUPPLY GRILLES RETURN GRILLE DUCTWORK Fan interlocked with f...

Page 10: ...sing threaded rods or chains At least 12 inches clearance from the access panel is needed to permit servicing the motor Loose fill or batt insulation can be installed over the unit if the unit s access doors can still be opened VENTERGY SERIES FANS RECTANGULAR DUCT FAN RDF INSTALLATION SUPPLEMENT Mounting Differences in bracket type and configuration may exist on some derived models Refer to suppl...

Page 11: ...ng method and mode of operation continuous manually or automatically controlled Proper duct design for friction losses with compatible supply orexhaustgrilles airflowandacousticpropertiesofthesupply exhaust grilles and compatible wall roof caps Methodofbalancingairflowsofmulti pointventilationsystems Consideration for potential condensation in the ducting or fan housing installation in an unheated...

Page 12: ... CONTRACTOR INSTALLER TO DETERMINE THE SUITABILITY OF THIS EQUIPMENT WITH RESPECT TO THE POTENTIAL FOR BACKDRAFTING NATURALLY VENTED FLUE DEVICES AND OR AFFECTING RADON ENTRY Impact of Exhaust Fans In especially tight homes heated with naturally vented appliances such as gas oil or wood fired furnaces boilers stoves or fireplaces the exhaust system may produce sufficient negative pressure indoors ...

Page 13: ...o observe the following safety warnings Warning TO REDUCETHE RISK OF FIRE USE ONLY GALVANIZED STEEL DUCTWORKWHEN REQUIRED TO USE METAL DUCT NOTE If only rigid ducting is allowed a metal sound attenuator shall be installed between the fan and the range hood NOTE If the fan is not connected to a range hood or a grille in the vicinity of the cooking surface other approved ducting may be used as descr...

Page 14: ...SOLETE OR UNSALABLE PRODUCT S ALDES MAY AT ITS DISCRETION ACCEPT RETURN OF SALABLE PRODUCT S SUBJECT TO A 25 RESTOCKING CHARGE 1 No product s will be accepted without a Return Materials Authorization RMA number RMA number can be obtained by calling ALDES at 1 800 255 7749 Have the Bill of Sale or proof of date of installation available 2 RMA must be clearly marked on outside of carton or delivery ...

Reviews: