background image

Setting  the  Airflow                                      

 

Twist the rotating adjustment ring until 

the desired airflow is reached. Reference 

the correlation table at right and printed 

on the device. No tools required.

Correlation Table                                           

 

MR MODULO

AIRFLOW & ZONE CONTROL

ADJUSTABLE CONSTANT AIRFLOW REGULATOR

IOM

READ AND SAVE THESE INSTRUCTIONS

1 Ø 

Ø

Ø

3 Ø 

m

3

/h CFM

K

100

59

J

110

65

I

120

71

H

130

76

G

140

82

E

150

88

C

160

94

A

190 112

P/N: 11016310

Ø 5" (125 mm) 

60-110 CFM

(100-190 m

3

/h)

m

3

/h CFM

U

225 132

S

250 147

Q

275 160

N

300 177

M

325 191

J

350 206

D

400 235

P/N: 11016313

Ø 8" (200 mm)

m

3

/h

CFM

U

300

175

R

355

205

O

400

235

L

450

265

I

500

295

G

550

325

A

650

385

P/N: 110163114

Ø 10" (250 mm)

P/N: 11016308   

Ø 4" (100 mm)

m

3

/h CFM m

3

/h CFM

L

15

9

-

-

J

20

12

-

-

H

25

15

-

-

F

30

18

-

-

E

35

21

70

41

D

40

24

75

44

C

45

26

80

47

A

55

32

90

53

P/N: 11016309

Ø 5" (125 mm) 

10-50 CFM (15-85 m

3

/h)

m

3

/h CFM m

3

/h CFM

L

15

9

-

-

I

25

15

-

-

G

-

-

60

35

F

30

18

65

38

D

-

-

70

41

C

-

-

75

44

B

45

26

80

47

A

50

29

85

50

P/N: 11016311

Ø 6" (150 mm)

m

3

/h

CFM

R

100

60

P

110

65

O

120

70

M

130

75

L

140

80

K

150

90

J

160

95

m

3

/h

CFM

H

170

100

G

180

105

F

190

110

E

200

120

D

210

125

A

240

140

Certain letters correspond to two setpoints: one with the clip, and one without the clip.

11016307   

Ø  3" (80 mm)

m

3

/h CFM m

3

/h CFM

K

20

12

-

-

J

25

15

-

-

H

30

18

-

-

G

35

21

45

26

F

40

24

50

29

B

45

26

60

35

SMALL DIAMETERS

LARGE DIAMETERS

EXHAUST AIR

SUPPLY AIR

Installation                                                                                         

 

• 

The MR Modulo will push-fit into circular ducts in close proximity to a take-off or terminal.

• 

Orient the MR Modulo according to the airflow direction indicated on the device.

• 

Horizontal or vertical mounting is acceptable.

• 

To avoid acoustic and aeraulic disturbance, provide the following distance between the  

device and the terminal  

(grille / diffuser / inlet):

• 

Exhaust Air: 1x the device diameter Ø

• 

Supply Air: 3x the device diameter Ø

360°

Summary of Contents for Ventergy IAQ-FSVS

Page 1: ...e superior solution for better indoor air quality comfort and energy efficiency VENTERGY IAQ FSVS RESIDENTIAL SYSTEM SOLUTIONS FILTERING SUPPLY VENTILATOR ACCESSORY KITS CONTINUOUS SUPPLY 2020 American ALDES Ventilation Corporation VentergySeries_IAQ FSVS_KIT_IOM_1020 Aldes reserves the right to modify its products at any time to introduce new technologies For more information contact your Aldes s...

Page 2: ...016309 Ø 5 125 mm 10 50 CFM 15 85 m3 h m3 h CFM m3 h CFM L 15 9 I 25 15 G 60 35 F 30 18 65 38 D 70 41 C 75 44 B 45 26 80 47 A 50 29 85 50 P N 11016311 Ø 6 150 mm m3 h CFM R 100 60 P 110 65 O 120 70 M 130 75 L 140 80 K 150 90 J 160 95 m3 h CFM H 170 100 G 180 105 F 190 110 E 200 120 D 210 125 A 240 140 Certain letters correspond to two setpoints one with the clip and one without the clip 11016307 Ø...

Page 3: ...uce new technologies For more information contact your Aldes sales advisor visit aldes na com call 1 800 255 7749 or find us on MR Modulo performance is not altered by clogging therefore it requires practically no special maintenance If the intended application includes air heavily loaded with grease or dust a fitting with an access panel or door such as that used for flame dampers should be used ...

Page 4: ...ssories such as knob dial plate mounting hardware instructions and individual carton All models are designed to be mounted into a standard 2 x 4 electrical wall box VARIABLE SPEED CONTROL FAN CONTROLS ISO 9001 2000 QMS 5 10 15 AMP CURRENT RATINGS SPEC IOM READ AND SAVE THESE INSTRUCTIONS 1 Models rated 10 A and above include mounting kit ELECTRICAL RATINGS AND AGENCY APPROVALS Part Number AC Line ...

Page 5: ...Temperature Test The non sinusoidal output voltage of a solid state speed control may increase motor heating Therefore it is necessary that a temperature test be performed to ensure that the motor is operating within manufacturer s specifications 5 Leads All leads are approximately 6 15 cm long and stripped 1 2 1 25 cm SAFETY WARNING Unit should be installed by a qualified electrician in accordanc...

Page 6: ...hen backdraft dampers are not present at other locations within the duct system Dimensions HIGH PERFORMANCE WALL HOODS ROOF CAPS WALL HOODS GRILLES DUCT FITTINGS WITH SCREENS OR GRAVITY DAMPERS 2020 American ALDES Ventilation Corporation and 2020 ALDES Canada HP_WallHoods_SPEC_0920 Aldes reserves the right to modify its products at any time to introduce new technologies For more information contac...

Page 7: ...For continuous operation the fan should be installed separately from the forced AHU to prevent moisture in the air from condensing inside cold ducts or cold air coming in contact with the heat exchanger The fan may be ducted so that fresh air is introduced into a living area via an overhead return FSVS140 VENTERGY SERIES FANS WARRANTY 3 YEARS FILTERING SUPPLY AIR VENTILATORS Fan and Motor The fan ...

Page 8: ...cy motor meets ENERGY STAR performance criteria Internally insulated with acoustic vapor barrier insulation REFERENCE RDF INSTALLATION SUPPLEMENT FOR ADDITIONAL INSTRUCTIONS AND WARRANTY INFORMATION Ducting the Fan Theductingfromthisfantotheoutsideofthebuildinghasastrongeffect ontheairflow noiseandenergyuseofthefan Usetheshortest straightest duct routing possible for best performance and avoid ins...

Page 9: ...CHEMATIC RUBBER FEET L Bracket secured to Building framing or concrete anchor FILTER ACCESS DOOR MOTOR ACCESS DOOR L Bracket secured to Wall framing or concrete wall with anchors GROMMETS FILTER ACCESS DOOR MOTOR ACCESS DOOR Suspension with threaded rods or cable through grommets in L Bracket Sold separately Refer to IOM text for details SUPPLY GRILLES RETURN GRILLE DUCTWORK Fan interlocked with f...

Page 10: ...sing threaded rods or chains At least 12 inches clearance from the access panel is needed to permit servicing the motor Loose fill or batt insulation can be installed over the unit if the unit s access doors can still be opened VENTERGY SERIES FANS RECTANGULAR DUCT FAN RDF INSTALLATION SUPPLEMENT Mounting Differences in bracket type and configuration may exist on some derived models Refer to suppl...

Page 11: ...ng method and mode of operation continuous manually or automatically controlled Proper duct design for friction losses with compatible supply orexhaustgrilles airflowandacousticpropertiesofthesupply exhaust grilles and compatible wall roof caps Methodofbalancingairflowsofmulti pointventilationsystems Consideration for potential condensation in the ducting or fan housing installation in an unheated...

Page 12: ... CONTRACTOR INSTALLER TO DETERMINE THE SUITABILITY OF THIS EQUIPMENT WITH RESPECT TO THE POTENTIAL FOR BACKDRAFTING NATURALLY VENTED FLUE DEVICES AND OR AFFECTING RADON ENTRY Impact of Exhaust Fans In especially tight homes heated with naturally vented appliances such as gas oil or wood fired furnaces boilers stoves or fireplaces the exhaust system may produce sufficient negative pressure indoors ...

Page 13: ...o observe the following safety warnings Warning TO REDUCETHE RISK OF FIRE USE ONLY GALVANIZED STEEL DUCTWORKWHEN REQUIRED TO USE METAL DUCT NOTE If only rigid ducting is allowed a metal sound attenuator shall be installed between the fan and the range hood NOTE If the fan is not connected to a range hood or a grille in the vicinity of the cooking surface other approved ducting may be used as descr...

Page 14: ...SOLETE OR UNSALABLE PRODUCT S ALDES MAY AT ITS DISCRETION ACCEPT RETURN OF SALABLE PRODUCT S SUBJECT TO A 25 RESTOCKING CHARGE 1 No product s will be accepted without a Return Materials Authorization RMA number RMA number can be obtained by calling ALDES at 1 800 255 7749 Have the Bill of Sale or proof of date of installation available 2 RMA must be clearly marked on outside of carton or delivery ...

Reviews: