background image

Product Description                         

Ventergy® Series Ventilator Fans represent years of engineering 

development to combine the energy efficiency and sound performance 

of a forward-curved fan with the durability and pressure characteristics 

of a backward-inclined impeller fan.

FSVS Filtering Supply Air Ventilators are highly versatile, continuous-

duty rated units for residential applications. They meet ENERGY STAR 

efficiency criteria for low energy consumption. The FSVS is designed to 

provide precise amounts of fresh outdoor air to the occupied space or 

forced AHU duct system.

The FSVS is designed to filter and distribute incoming fresh air and prevent 

the introduction of contaminants as a result of unwanted infiltration 

through leaks in the building’s envelope. By slightly pressurizing 

the structure, the FSVS also reduces the risk of backdrafting heating 

appliances, water heaters, and fireplaces. The quiet, continuous-duty, 

energy-efficient, external-rotor motor with permanently sealed bearings 

provides many years of maintenance-free performance.

Construction                                    

The FSVS is constructed of heavy-gauge galvanized steel to prevent 

corrosion caused by moisture. The cabinet is internally lined with 

acoustic, closed-cell foam insulation that acts as a vapor barrier. This 

allows installation directly above living spaces or in unheated plenum 

spaces without concern for noise or condensation.

Controls                                         

The fan can be operated manually or automatically by a programmable 

timer, dehumidistat, or other appropriate electronic switch device.  The 

fan may also be operated in conjunction with a variable speed control. 

The fan may be interlocked with a forced air handling unit for optimal 

air distribution. For continuous operation, the fan should be installed 

separately from the forced AHU to prevent moisture in the air from 

condensing inside cold ducts, or cold air coming in contact with the 

heat exchanger. The fan may be ducted so that fresh air is introduced 

into a living area via an overhead return. 

FSVS140

VENTERGY

®

 SERIES FANS

WARRANTY

YEARS

FILTERING SUPPLY AIR VENTILATORS

Fan and Motor                                   

       

The fan motor is an energy-efficient, permanent-split-capacitor type 

with external-rotor design. Totally sealed to protect against moisture and 

contaminants, it incorporates permanently lubricated sealed bearings 

and automatic-reset thermal-overload protection. It is designed and 

certified for continuous duty or intermittent operation.

The fan uses a backward-inclined impeller design that minimizes dust 

collection on blades. Each fan is statically and dynamically balanced at 

the factory to eliminate vibration and ensure quiet operation.

Locating and Installing                       

 

The compact dimensions and versatile mounting options permit 

installation above drop ceilings, between ceiling joists, or within a small 

soffit location. They can be installed horizontally or vertically.

Serviceability                                    

 

The entire motor and fan assembly is mounted on a drop-down hinged-

access panel for simple service and inspection. It can be removed from 

the fan housing without disassembling the duct connections. The filter/

supply air manifold section includes a separate drop-down access panel 

for filter inspection or removal and airflow rate adjustments of each 

supply duct airflow regulator without disconnecting the unit from the 

duct. Tools are not required to access the filters.

Accessories                                     

 

Accessory kits are available to facilitate installation and enhance operation. 

Accessories kits are sold separately. Please visit aldes-na.com, or contact 

your local Aldes distributor for details.

IOM

READ AND SAVE THESE INSTRUCTIONS

Summary of Contents for Ventergy IAQ-FSVS

Page 1: ...e superior solution for better indoor air quality comfort and energy efficiency VENTERGY IAQ FSVS RESIDENTIAL SYSTEM SOLUTIONS FILTERING SUPPLY VENTILATOR ACCESSORY KITS CONTINUOUS SUPPLY 2020 American ALDES Ventilation Corporation VentergySeries_IAQ FSVS_KIT_IOM_1020 Aldes reserves the right to modify its products at any time to introduce new technologies For more information contact your Aldes s...

Page 2: ...016309 Ø 5 125 mm 10 50 CFM 15 85 m3 h m3 h CFM m3 h CFM L 15 9 I 25 15 G 60 35 F 30 18 65 38 D 70 41 C 75 44 B 45 26 80 47 A 50 29 85 50 P N 11016311 Ø 6 150 mm m3 h CFM R 100 60 P 110 65 O 120 70 M 130 75 L 140 80 K 150 90 J 160 95 m3 h CFM H 170 100 G 180 105 F 190 110 E 200 120 D 210 125 A 240 140 Certain letters correspond to two setpoints one with the clip and one without the clip 11016307 Ø...

Page 3: ...uce new technologies For more information contact your Aldes sales advisor visit aldes na com call 1 800 255 7749 or find us on MR Modulo performance is not altered by clogging therefore it requires practically no special maintenance If the intended application includes air heavily loaded with grease or dust a fitting with an access panel or door such as that used for flame dampers should be used ...

Page 4: ...ssories such as knob dial plate mounting hardware instructions and individual carton All models are designed to be mounted into a standard 2 x 4 electrical wall box VARIABLE SPEED CONTROL FAN CONTROLS ISO 9001 2000 QMS 5 10 15 AMP CURRENT RATINGS SPEC IOM READ AND SAVE THESE INSTRUCTIONS 1 Models rated 10 A and above include mounting kit ELECTRICAL RATINGS AND AGENCY APPROVALS Part Number AC Line ...

Page 5: ...Temperature Test The non sinusoidal output voltage of a solid state speed control may increase motor heating Therefore it is necessary that a temperature test be performed to ensure that the motor is operating within manufacturer s specifications 5 Leads All leads are approximately 6 15 cm long and stripped 1 2 1 25 cm SAFETY WARNING Unit should be installed by a qualified electrician in accordanc...

Page 6: ...hen backdraft dampers are not present at other locations within the duct system Dimensions HIGH PERFORMANCE WALL HOODS ROOF CAPS WALL HOODS GRILLES DUCT FITTINGS WITH SCREENS OR GRAVITY DAMPERS 2020 American ALDES Ventilation Corporation and 2020 ALDES Canada HP_WallHoods_SPEC_0920 Aldes reserves the right to modify its products at any time to introduce new technologies For more information contac...

Page 7: ...For continuous operation the fan should be installed separately from the forced AHU to prevent moisture in the air from condensing inside cold ducts or cold air coming in contact with the heat exchanger The fan may be ducted so that fresh air is introduced into a living area via an overhead return FSVS140 VENTERGY SERIES FANS WARRANTY 3 YEARS FILTERING SUPPLY AIR VENTILATORS Fan and Motor The fan ...

Page 8: ...cy motor meets ENERGY STAR performance criteria Internally insulated with acoustic vapor barrier insulation REFERENCE RDF INSTALLATION SUPPLEMENT FOR ADDITIONAL INSTRUCTIONS AND WARRANTY INFORMATION Ducting the Fan Theductingfromthisfantotheoutsideofthebuildinghasastrongeffect ontheairflow noiseandenergyuseofthefan Usetheshortest straightest duct routing possible for best performance and avoid ins...

Page 9: ...CHEMATIC RUBBER FEET L Bracket secured to Building framing or concrete anchor FILTER ACCESS DOOR MOTOR ACCESS DOOR L Bracket secured to Wall framing or concrete wall with anchors GROMMETS FILTER ACCESS DOOR MOTOR ACCESS DOOR Suspension with threaded rods or cable through grommets in L Bracket Sold separately Refer to IOM text for details SUPPLY GRILLES RETURN GRILLE DUCTWORK Fan interlocked with f...

Page 10: ...sing threaded rods or chains At least 12 inches clearance from the access panel is needed to permit servicing the motor Loose fill or batt insulation can be installed over the unit if the unit s access doors can still be opened VENTERGY SERIES FANS RECTANGULAR DUCT FAN RDF INSTALLATION SUPPLEMENT Mounting Differences in bracket type and configuration may exist on some derived models Refer to suppl...

Page 11: ...ng method and mode of operation continuous manually or automatically controlled Proper duct design for friction losses with compatible supply orexhaustgrilles airflowandacousticpropertiesofthesupply exhaust grilles and compatible wall roof caps Methodofbalancingairflowsofmulti pointventilationsystems Consideration for potential condensation in the ducting or fan housing installation in an unheated...

Page 12: ... CONTRACTOR INSTALLER TO DETERMINE THE SUITABILITY OF THIS EQUIPMENT WITH RESPECT TO THE POTENTIAL FOR BACKDRAFTING NATURALLY VENTED FLUE DEVICES AND OR AFFECTING RADON ENTRY Impact of Exhaust Fans In especially tight homes heated with naturally vented appliances such as gas oil or wood fired furnaces boilers stoves or fireplaces the exhaust system may produce sufficient negative pressure indoors ...

Page 13: ...o observe the following safety warnings Warning TO REDUCETHE RISK OF FIRE USE ONLY GALVANIZED STEEL DUCTWORKWHEN REQUIRED TO USE METAL DUCT NOTE If only rigid ducting is allowed a metal sound attenuator shall be installed between the fan and the range hood NOTE If the fan is not connected to a range hood or a grille in the vicinity of the cooking surface other approved ducting may be used as descr...

Page 14: ...SOLETE OR UNSALABLE PRODUCT S ALDES MAY AT ITS DISCRETION ACCEPT RETURN OF SALABLE PRODUCT S SUBJECT TO A 25 RESTOCKING CHARGE 1 No product s will be accepted without a Return Materials Authorization RMA number RMA number can be obtained by calling ALDES at 1 800 255 7749 Have the Bill of Sale or proof of date of installation available 2 RMA must be clearly marked on outside of carton or delivery ...

Reviews: