25
Digital Inverter Generator with Pure Sine Wave
AFTER SALES SUPPORT
e-mail: info.aldi@positecgroup.com
1300 889 028
MODEL: №. XG-KF2000 • 03/2020 • 700069
(toll free)
AFTER SALES SUPPORT
(toll free)
e-mail: info.aldi@positecgroup.com
1300 889 028
Digital Inverter Generator with Pure Sine Wave
MODEL: №. XG-KF2000 • 03/2020 • 700069
2. Allow the engine to slow down and idle for approximately 15-30 seconds.
Remove any appliances connected to either of the 2 AC sockets.
3. Press the engine On/Off switch (2) to the “OFF” position as indicated by an
“O” (Fig. U). The unit will stop running and is shut down.
Now follow the normal starting procedure to restart the generator.
Emergency Stop, and / or failure of On/off Switches (NOT
RECOMMENDED EXCEPT IN EMERGENCY)
In the case of an emergency that requires the
generator to be shut down as fast as possible:
1. Turn “OFF” the 240Va.c Outlet Power On/Off
switch (1). If the switches have failed and power is
still going to the appliance outlets quickly move
to step 2.
2. Press the engine On/Off switch (2) to the “OFF”
position as indicated by an “O” (Fig. U). The unit
should stop running. If the switches have not shut
down the generator, you can quickly remove / pull out the plugs of the
appliances plugged into the AC sockets (9) that need to be shut down.
3. Where the engine keeps operating, don’t panic, turn the fuel lever / tap
(23)
clockwise
to the “OFF” position (Fig. T). The generator will run out of
fuel within one minute and then stop.
Do not use the generator again until the generator is serviced by an
authorised service agent and the product is repaired, checked and the fault
corrected.
As always in an emergency protect people that could be in harms way first.
Carbon build up
Carbon build up can be a problem on generators as the loading on the engine
can vary considerably. Running the generator at low loading for extended
periods can cause carbon build up.
Carbon build up in the engine can be reduced by operating the generator
at approximately 75% of rated load for 25% of the time the generator is
used. i.e, if the generator is used for 4 hours on low load i.e 800W or less, run
the generator for 1 hour at around 75% of rating. This is only required if the
generator has been used for less than 25% of rated load for extended periods.
i.e 2 hrs or more.
NOTE:
For best operation and long engine life use unleaded fuel without
ethanol.
U.