Indicators
This generator has three main LED indicators to indicate to the operator
various conditions as follows:
1. Low oil indicator (Fig D)
The low oil indicator light (4) is a
yellow LED and will illuminate when
the oil level of the generator is too
low. The generator will stop operating
within 10 seconds if the yellow
light comes on. The yellow LED will
illuminate when the generator is being attempted to start if the oil is low, i.e.
when the cord is being pulled, the yellow LED will glow if there is insufficient
oil. In this condition, the generator will not start. In this condition you need
to add oil for the generator to operate.
2. Load Status indicator (Fig E)
The red load status indicator light
(5) advises the operator that a fault
has been detected and the power
supply to the control panel has been
interrupted. When the red load status
indicator is operating red, there is NO
240Va.c. available to the control panel.
When the engine is running the load status indicator light (5) flashes under
the following conditions:
a. Flashing once indicates low voltage protection, caused by the engine
rotation speed not meeting the specified requirements.
b. Flashing twice indicates the engine is overheated, caused by high
temperature.
Preparation information
Preparation Information
c. Flashing 3 times indicates overload protection caused by an excessive
electrical overload.
d. Flashing 4 times indicates there is an electrical problem most likely caused
by a short circuit.
In any of the above instances, when the red load status indicator light
(5) turns on, the power supply to the control panel will be disconnected
automatically.
NOTE: The engine must be stopped and the issue resolved before the
power supply will be restored.
3. Power Supply indicator (Fig F)
The power supply indicator light (6) is
a green LED. It will only display green
when there is a 240V output available,
thus the generator must be operating.
This indicator will remain on when
the generator is operating and has
240Va.c. available to the control panel,
with or without appliances connected
to the AC sockets (9).
In an overload condition, there is no
240Va.c. available to the panel so the green indicator will not operate.
Preparing the Generator
It is important to check the generator before you commence operating
the unit.
IMPORTANT. Ensure that the engine has oil. When leaving the factory,
this generator has NO OIL in the engine.
NOTE. The engine will not start if the generator has no oil.
Checking the Engine Fuel
IMPORTANT: Fuel goes off after about 3-4 months. If you find your generator
does not start, first change the fuel in the tank with newly purchased fresh
unleaded fuel. Do not use ethanol based fuels.
IMPORTANT: If replacing old fuel from the generator ensure to drain the old
fuel from the carburettor bowl until the new fuel drains from the bowl. Drain
the bowl via the fuel drain (10).
D.
E.
Preparation Information
F.