Digital Inverter Generator with Pure Sine Wave
AFTER SALES SUPPORT
e-mail: help@powertoolsupport.com
1800 909 909
MODEL: №. EP2800i • 09/2018 • 62007
(toll free)
AFTER SALES SUPPORT
(toll free)
Digital Inverter Generator with Pure Sine Wave
e-mail: help@powertoolsupport.com
1800 909 909
MODEL: №. EP2800i • 09/2018 • 62007
24
25
Normal procedure for Stopping the Engine
(Full shut down and Store)
1. Turn “OFF” the 240Va.c Outlet Power On/Off switch (1) by pushing the
switch to the right hand side. (Fig U).
2. Remove any appliances connected to either of the 2 outlets (Fig K).
3. Allow the engine to slow down and idle for approx 15-30 seconds.
4. Press the engine On/Off switch (2) to the “OFF” position as indicated
by an “O” (Fig. V). The unit will stop running .
5. Turn the fuel lever / tap (23) anti clockwise to the “OFF” position (Fig. W)
Overload procedure for restarting and resetting the engine
1. Turn “OFF” the 240Va.c Outlet Power On/Off switch (1) by pushing the
switch to the right hand side. (Fig U).
2. Allow the engine to slow down and idle for approximately 15-30 seconds.
Remove any appliances connected to either of the 2 AC sockets.
3. Press the engine On/Off switch (2) to the “OFF” position as indicated by an
“O” (Fig. X). The unit will stop
running and is shut down.
Now follow the normal starting
procedure to restart the generator.
WARNING: All appliances are rated differently. This generator will work
only with Australian approved rated appliances with an input voltage of
220-240Va.c (Fig T). Check your appliances meet this requirement on its
rating label before using them. In simple terms if you cant use the product
in your home you definitely cannot use it on this generator.
Overload condition ( Where the appliances want more
power then the generator can provide)
Once operating, If the AC side of the generator becomes overloaded , the
red load status indicator (5) LED will illuminate. The generator will continue
to supply 240Va.c output for a very short time, but if the load is not reduced,
the 240V supply will be automatically shut down. To reduce load firstly
you can stop using one appliance and turn it off , see if that rectifies the
problem. If not refer to page 15 on loading’s and how they work. If this does
NOT solve your problem, or you do not reduce load fast enough, the output
of the generator will be automatically shut down, and the petrol motor
will continue to run. You will now need to reset the overload condition by
shutting down the petrol motor (Fig S), and thus restart the engine after the
load being applied to the generator has been reduced. Refer to the Overload
procedure for re-starting and re-setting the engine. Always connect the
largest appliance you want to run first allowing it time to draw current to
start . After 20-30 seconds connect the second appliance.
T.
Operation
Operation
X.
OFF
V.
U.
W.
ON
OFF
OFF
OFF