26
27
Emergency Stop, and / or failure of On/off Switches
(NOT RECOMMENDED EXCEPT IN EMERGENCY)
In the case of an emergency that requires the generator to be shut down as
fast as possible:
1. Turn “OFF” the 240Va.c Outlet Power On/Off switch (1). If the switches
have failed and power is still going to the appliance outlets quickly move
to step 2.
2. Press the engine On/Off switch (2) to the “OFF” position as indicated by an
“O” (Fig. X). The unit should stop running.
If the switches have not shut down the generator, you can quickly remove
/ pull out the plugs of the appliances plugged into the AC sockets (9) that
need to be shut down.
3. Where the engine keeps operating, don’t panic, turn the fuel lever / tap
(23) anti clockwise to the “OFF” position (Fig. W). The generator will run out
of fuel within one minute and then stop.
Do not use the generator again until the generator is serviced by an
authorised service agent and the product is repaired, checked and
the fault corrected.
As always in an emergency protect people that could be in harms way first.
Carbon build up
Carbon build up can be a problem on generators as the loading on the
engine can vary considerably. Running the generator at low loading for
extended periods can cause carbon build up.
Carbon build up in the engine can be reduced by operating the generator at
approximately 75% of rated load for 25% of the time the generator is used.
i.e, if the generator is used for 4 hours on low load i.e 800W or less, run the
generator for 1 hour at around 75% of rating. This is only required
if the generator has been used for less than 25% of rated load for extended
periods. i.e 2 hrs or more.
NOTE: For best operation and long engine life use unleaded fuel
without ethanol.
Operation
Storage
Storage
• Never store generator with fuel in the tank indoors or in enclosed, poorly
ventilated areas, where fumes can reach an open flame, spark or pilot
light as on a furnace, water heater, clothes dryer or other gas appliances.
• Ensure the fuel tank and carburettor are BOTH fully drained of fuel.
With the fuel tap in the open position, then open the fuel drain (10) on
the carburettor to drain the fuel totally from the fuel tank (26).
• Check the fuel tap / lever (23) is turned off after draining the tank and
carburettor. (Fig T).
• Drain and replace the engine oil.
• Clean the generator with a damp soft cloth with mild detergent.
• Do not clean the generator with water.
• Check all nuts bolts and fasteners. Ensure they are tightened if needed
before storage.