Digital Inverter Generator with Pure Sine Wave
AFTER SALES SUPPORT
e-mail: help@powertoolsupport.com
1800 909 909
MODEL: №. EP2800i • 09/2018 • 62007
(toll free)
AFTER SALES SUPPORT
(toll free)
Digital Inverter Generator with Pure Sine Wave
e-mail: help@powertoolsupport.com
1800 909 909
MODEL: №. EP2800i • 09/2018 • 62007
34
35
Recycle unwanted materials instead of disposing of them as waste.
All tools, hoses and packaging should be sorted, taken to the local
recycling centre and disposed of in an environmentally safe way.
Dispose of used motor oil in a manner that is compatible with the
environment.
We suggest you take it in a sealed container to your local service station for
reclamation. Do not throw it in the trash or pour it into the earth.
Great care has gone into the manufacture of this product and it should
therefore provide you with years of good service when used properly.
In the event of product failure within its intended use over the course of
the first 3 years after the date of purchase, we will remedy the problem as
quickly as possible once it has been brought to our attention. In the unlikely
event of such an occurrence, or if you require any information about the
product please contact us via our after sales support services, details of
which can be found in this manual and on the product itself. After Sales
Support TEL: 1800 909 909
If you are having difficulty in using your product, you can find instructional
Know How videos on our website, https://help.tools/ by clicking on the
“How to videos” link.
If you have any issues with the operation of your product, please take it with
a copy of your receipt to one of our National Service Agents for repair or call
us 1800 909 909 for advice.
A listing of our Service Agents is included with your product, however,
you can also find our most updated listing on our website
https://help.tools/ by clicking on the Service Agent link.
Environmental Protection
Troubleshooting
Service Support
Environmental Protection
What your 3 year warranty means
Troubleshooting
Trouble
Possible cause
Suggested remedy
Engine will not start
1. Low on fuel or oil content
1a Fully fill tank. Ensure fuel is fresh
1b Ensure oil is at the the correct level.
Refer page 21-22 of this manual.
1c Ensure the generator is horizontal and
not on an angle
1d Turn Off the fuel tap / lever (23).
Loosen the carburettor drain screw.
Allow the fuel in the carburettor bowl
to totally drain. When the fuel has
stopped draining, open the fuel tap /
lever (23) on the tank and fuel starts
running out of the carburettor drain. If
so, tighten the screw on the drain and
allow the carburettor to fill with petrol.
1e If the fuel from the tank does not pass
through the carburettor drain above,
you need to drain the fuel tank (27),
remove the fuel tap / lever (23) and
inspect the fuel extension filter (22).
2. Engine On/Off switch (2) in “Off”
position
2. Press the engine On/Off switch (2) to
the “ON” position as indicated by an “I”.
3. Faulty spark plug (20)
3. Replace or clean spark plug (20)
Refer page 30.
4. Choke lever (16) in wrong position
4. Adjust choke lever (16) accordingly
Refer to page 23.
5. Fuel shut-off valve in closed position
5. Open fuel shut-off valve
6. Unit loaded during start-up
6. Remove load from unit
7. Spark plug (20) wire loose
7. Attach wire to spark plug (20)
8. Old fuel in carburettor
8. Fuel will deteriorate in the carburettor
fuel bowl very quickly. Open the drain
screw in the bowl of the carburettor
until fresh fuel runs through.
9. If all of the above checked ok
9. Take unit to service centre