700W AIRLESS SPRAY STATION
23
700W AIRLESS SPRAY STATION
22
g) Replace the cleaned spray tip, saddle seat and washer back to the spray
guard assembly.
h) Connect the spray hose to the spray gun.
10.4 Cleaning the suction tube and return tube
a) Lock the trigger, turn off the airless spray station and turn the Prime/Spray
knob to PRIME position.
b) Disconnect the suction tube and return tube and remove
suction tube
filter by twisting and prying it out of the retainer at the end of the
suction tube.
c) Clean the suction tube, suction tube filter and return hose with an
appropriate cleaning solution.
d) Replace the cleaned suction tube, suction tube filter and return tube.
e) Submerge the suction tube and return tube into a bucket of new cleaning
solution.
f) Turn the Prime/Spray knob to PRIME position, turn on the airless spray
station, aim the spray gun into a waste container and pull the trigger to
relieve the pressure.
g) Allow the pump to circulate cleaning solution through the suction tube
and return tube for about 2-3 minutes.
h) Turn off the airless spray station.
10.5 Cleaning the spray hose
a) Follow the steps outlined in section 9.5 "Priming and purging the spray
hose"
10.6 Cleaning the suction tube inlet port (Fig.17,18)
a) Cleaning or servicing the suction tube inlet port may be required if the
airless spray station has a priming problem.
b) Unscrew the three suction tube inlet port nuts (H).
c) Disassemble the suction tube inlet port assembly (I).
d) Clean the housing, carbide seat, ball, o-rings, rubber seal ring and inlet
port valve with appropriate cleaning solution to remove excess paint and
rust.
e) Check the two rubber seal rings, clean and lubricate with a light machine
oil.
e) Re-assemble and replace the suction tube inlet port.