Cleaning and maintenance
24
www.isc-gmbh.info
GB
AFTER SALES SUPPORT
24
IRE
GB
IRE
0044 151 649 1500
0044 1890 946 244
7. Let the condensed water drain completely.
8. Close the drain cock for condensed water.
Repeat the process regularly depending on how much and how intensely you use the
device (e.g. weekly).
Adding and changing oil
NOTICE!
Risk of damage!
Unsuitable oil or an insufficient or excessive amount of oil in the compressor
could damage it.
− Before each use, check the oil level and, if applicable, add oil or drain off
excess oil.
− Use multigrade oils SAE 10W40/15W40.
− Perform a complete oil change no later than after 100 operating hours or
6 months.
− Fill the compressor with no more than 175 ml of oil.
NOTICE!
Risk of pollution!
Used oil that ends up in the environment or the sewer system will pollute the
environment.
− Only dispose of used oil as hazardous waste in accordance with valid local
guidelines.
Tip:
Use synthetic SAE 10W40 oil for operation at an ambient temperature
of +5 °C to +40 °C. Synthetic oil has the advantage that its character-
istics remain unchanged at different temperatures, e.g. in the sum-
mer or winter.
Tip:
The crankcase is capable of holding approx. 175 ml of oil. You can
determine the current oil level with the view window of the oil drain
plug.
Summary of Contents for Workzone WAC 3050/1
Page 4: ...B C A 4 5 1 2 20 19 3 13 18 14 16 15 7 8 9 10 6 7 12 21 11 22 17 7 4 4 GB IRE...
Page 5: ...H F G D E Max 10 min max 23 2 19 16 12 14A 14B 20 5 GB IRE...
Page 34: ...34 www isc gmbh info GB AFTER SALES SUPPORT 34 IRE GB IRE 0044 151 649 1500 00441890946244...
Page 37: ......
Page 38: ......
Page 39: ......