6. Before starting up
m
Attention!
Before you connect the equipment to the mains supply make sure that the data on
the rating plate are identical to the mains data.
•
Check the equipment for damage which may have occurred in transit. Report
any damage immediately to the transport company which was used to deliver
the compressor.
•
Install the compressor near the point of consumption.
•
Avoid long air lines and supply lines (extension cables).
•
Make sure that the intake air is dry and dustfree.
•
Do not install the compressor in a damp or wet room.
•
The compressor may only be used in suitable rooms (with good ventilation and
an ambient temperature from +5 °C to 40 °C). There must be no dust, acids,
vapors, explosive gases or inflammable gases in the room.
•
The compressor is designed to be used in dry rooms. It is prohibited to use the
compressor in areas where work is conducted with sprayed water.
7. Attachment and operation
m
Attention!
You must fully assemble the appliance before using it for the first time!
MAINS CONNECTION
•
The compressor is equipped with a mains cable with shock-proof plug. This can
be connected to any 220 - 240 V ~ 50 Hz shock-proof socket.
•
Before you use the machine, make sure that the mains voltage is the same as
the operating voltage (see the rating plate).
•
Long supply cables, extensions, cable reels etc. cause a drop in voltage and
can impede motor start-up.
•
At low temperatures below +5°C, sluggishness may make starting difficult or
impossible.
COMPRESSED AIR HOSE WITH QUICK-LOCK COUPLING (4)
Connecting:
Insert the nipple of the air tool into the quick-lock coupling (4), the sleeve will spring
forward automatically. (Fig. 2)
Disconnecting:
Pull back the sleeve and remove the tool. (Fig. 2.1)
Attention!
When releasing the quick-lock coupling, be sure to hold the coupling
piece to protect yourself against injury from the rebounding hose.
AUS
Before starting up / Attachment and operation
AIR FORCE
14
AFTER SALES SUPPORT
support@scheppach.com.au
1300 855 831
MODEL: AIR FORCE PRODUCT CODE: 56102 02/2018