If the supply cord is damaged, it must be replaced by a special cord or assembly 

available from the manufacturer or its service agent.

Please provide the following information in the event of any enquiries:

• 

Type of current for the motor

• 

Machine data - type plate

10. Troubleshooting

Fault

Possible cause

Remedy

The compressor 

does not start.

•  No supply voltage.

• 

Insufficient supply 

voltage.

•  Outside temperature is 

too low.

•  Motor is overheated.

•  Check the supply voltage, the  

power plug and the socket-outlet.

•  Make sure that the extension cable 

is not too long. Use an extension 

cable with large enough wires.

•  Never operate with an outside  

temperature of below +5° C.

•  Allow the motor to cool down. If 

necessary, remedy the cause of the 

overheating.

The compressor 

starts but there 

is no pressure.

•  The seals are dam-

aged.

•  Check the seals and have any  

damaged seals replaced by a  

service center.

The compres-

sor starts but 

the tools do not 

start.

•  The hose connections 

have a leak.

•  A quick-lock coupling 

has a leak.

•  Check the compressed air hose 

and tools and replace if necessary.

•  Check the quick-lock coupling and 

replace if necessary.

11. Maintenance & Cleaning

m

 Important!

Pull out the power plug before doing any cleaning and maintenance work on the 

equipment. Risk of injury from electric shock!

m

 Important!

Wait until the equipment has cooled down completely! Risk of burns!

AUS

Electrical connection / Troubleshooting/Maintenance&Cleaning

AIR FORCE

18

AFTER SALES SUPPORT

 

support@scheppach.com.au

 

 

1300 855 831

MODEL: AIR FORCE  PRODUCT CODE:  56102  02/2018

Summary of Contents for WORKZONE

Page 1: ...tees that our exclusive brand products are developed to our stringent quality specifications If you are not entirely satisfied with this product please return it to your nearest ALDI store within 60 d...

Page 2: ...for cycle tyre valves 1x Adapter for screw valves e g on inflatable dinghies 1x Universal adapter for valves with internal of approx 6 mm 1x Universal adapter for valves with internal of approx 8 mm 1...

Page 3: ...tion The equipment is remote controlled and may start up without warning Prohibition Do not open the cock before the air hose is attached Symbol Category II This device is equipped with dual in sulati...

Page 4: ...instructions contain important notes on how to work safely properly and economically with your machine and how to avoid dangers save repair costs reduce downtime and increase the reliability and work...

Page 5: ...al adapter for valves with internal of approx 8 mm 3 Scope of delivery Open the packaging and remove the device carefully Remove the packaging material as well as the packaging and transport bracing i...

Page 6: ...e risk of injuries and damage Read the directions with due care If you give the equipment to any other person give them these operating instructions as well We assume no liability for injuries or dama...

Page 7: ...luence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury b Use personal protective equipment Always wear eye protection Protec ti...

Page 8: ...power tools out of the reach of children and do not allow per sons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained us...

Page 9: ...tion provided by the manufacturers of such liquids The details and designations of the Ordinance on Hazardous Substances which are displayed on the outer packaging of the processed material must be ob...

Page 10: ...d operation m Attention You must fully assemble the appliance before using it for the first time MAINS CONNECTION The compressor is equipped with a mains cable with shock proof plug This can be connec...

Page 11: ...se refer to the following overview Fitting the accessory Attach the compressed air tools to the tyre pressure gauge G which has to be connected to the pressure hose 5 Using the equipment as a blow out...

Page 12: ...as pools which are fitted with a screw valve Vent adapter Fig 1 Item H Range of applications For deflation valves You can find a deflation valve combined with other valves standard valve screw valve...

Page 13: ...ndows or doors Kinks where the connection cable has been improperly fastened or routed Places where the connection cables have been cut due to being driven over Insulation damage due to being ripped o...

Page 14: ...otor to cool down If necessary remedy the cause of the overheating The compressor starts but there is no pressure The seals are dam aged Check the seals and have any damaged seals replaced by a servic...

Page 15: ...ipment You must disconnect the hose and any spraying tools from the compressor be fore cleaning Do not clean the compressor with water solvents or the like 12 Storage m Important Pull out the mains pl...

Page 16: ...terial circulation saves raw materials and reduces waste disposal costs Parts of packaging e g foils styropor can be dangerous to children Risk of suffocation Keep packaging away from children and dis...

Page 17: ...product that the consumer has under the Competition and Consumer Act 2010 and similar state and territory laws Our goods come with guarantees that cannot be excluded under the Australian Consumer Law...

Page 18: ...e lost We recommend you save this data elsewhere prior to sending the product for repair You should also be aware that rather than repairing goods we may replace them with refurbished goods of the sam...

Reviews: