background image

m

 Important!

Always de-pressurize the equipment before carrying out any cleaning and  

maintenance work! Risk of injury! To do so, use the tyre pressure gauge as a  

blow-out pistol and press the trigger lever until no more air escapes.

11.1 Cleaning

• 

Keep the equipment free of dirt and dust as far as possible. Wipe the equipment 

with a clean cloth or blow it down with compressed air at low pressure.

• 

We recommend that you clean the equipment immediately after you use it.

• 

Clean the equipment regularly with a damp cloth and some soft soap. Do not 

use cleaning-agents or solvents; these may be aggressive to the plastic parts in 

the equipment. Ensure that no water can get into the interior of the equipment.

• 

You must disconnect the hose and any spraying tools from the compressor be-

fore cleaning. Do not clean the compressor with water, solvents or the like.

12. Storage

m

 Important!

Pull out the mains plug and ventilate the equipment and all connected pneumatic 

tools. Switch off the compressor and make sure that it is secured in such a way that 

it cannot be started up again by any unauthorized person.

m

 Important!

Store the compressor only in a dry location which is not accessible to unauthorized 

persons. 

Releasing excess pressure

Release the excess pressure by switching off the compressor and using the com-

pressed air which is still left in the pressure vessel, e.g. with a compressed air tool 

running in idle mode or with a blow-out pistol.

AUS

AIR FORCE

Maintenance&Cleaning / Storage

AFTER SALES SUPPORT

19

 

 

1300 855 831

 

support@scheppach.com.au

MODEL: AIR FORCE  PRODUCT CODE:  56102  02/2018

Summary of Contents for WORKZONE

Page 1: ...tees that our exclusive brand products are developed to our stringent quality specifications If you are not entirely satisfied with this product please return it to your nearest ALDI store within 60 d...

Page 2: ...for cycle tyre valves 1x Adapter for screw valves e g on inflatable dinghies 1x Universal adapter for valves with internal of approx 6 mm 1x Universal adapter for valves with internal of approx 8 mm 1...

Page 3: ...tion The equipment is remote controlled and may start up without warning Prohibition Do not open the cock before the air hose is attached Symbol Category II This device is equipped with dual in sulati...

Page 4: ...instructions contain important notes on how to work safely properly and economically with your machine and how to avoid dangers save repair costs reduce downtime and increase the reliability and work...

Page 5: ...al adapter for valves with internal of approx 8 mm 3 Scope of delivery Open the packaging and remove the device carefully Remove the packaging material as well as the packaging and transport bracing i...

Page 6: ...e risk of injuries and damage Read the directions with due care If you give the equipment to any other person give them these operating instructions as well We assume no liability for injuries or dama...

Page 7: ...luence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury b Use personal protective equipment Always wear eye protection Protec ti...

Page 8: ...power tools out of the reach of children and do not allow per sons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained us...

Page 9: ...tion provided by the manufacturers of such liquids The details and designations of the Ordinance on Hazardous Substances which are displayed on the outer packaging of the processed material must be ob...

Page 10: ...d operation m Attention You must fully assemble the appliance before using it for the first time MAINS CONNECTION The compressor is equipped with a mains cable with shock proof plug This can be connec...

Page 11: ...se refer to the following overview Fitting the accessory Attach the compressed air tools to the tyre pressure gauge G which has to be connected to the pressure hose 5 Using the equipment as a blow out...

Page 12: ...as pools which are fitted with a screw valve Vent adapter Fig 1 Item H Range of applications For deflation valves You can find a deflation valve combined with other valves standard valve screw valve...

Page 13: ...ndows or doors Kinks where the connection cable has been improperly fastened or routed Places where the connection cables have been cut due to being driven over Insulation damage due to being ripped o...

Page 14: ...otor to cool down If necessary remedy the cause of the overheating The compressor starts but there is no pressure The seals are dam aged Check the seals and have any damaged seals replaced by a servic...

Page 15: ...ipment You must disconnect the hose and any spraying tools from the compressor be fore cleaning Do not clean the compressor with water solvents or the like 12 Storage m Important Pull out the mains pl...

Page 16: ...terial circulation saves raw materials and reduces waste disposal costs Parts of packaging e g foils styropor can be dangerous to children Risk of suffocation Keep packaging away from children and dis...

Page 17: ...product that the consumer has under the Competition and Consumer Act 2010 and similar state and territory laws Our goods come with guarantees that cannot be excluded under the Australian Consumer Law...

Page 18: ...e lost We recommend you save this data elsewhere prior to sending the product for repair You should also be aware that rather than repairing goods we may replace them with refurbished goods of the sam...

Reviews: