background image

12

4.9 Display lighting:

Press the 

SNOOZE

 button at the top of the indoor unit to switch on the display lighting. After you release 

the button, the light will turn off after 5 seconds

5.  ALARM CLOCK
5.1 Introduction:

The WS-4700 allows you to program an alarm (wake-up) time.

You may also enable an ice alert for this wake-up function: when the outdoor temperature is below -3°C, 

the alarm signal will sound 30 minutes before the time you’ve programmed.

5.2 Alarm time setup:

1.  press and hold the   button at the rear of the indoor for 2 seconds until the hour display starts 

flashing

2. use  /  to set the hours, briefly press   and the minute display starts flashing

3. use  /  to set the minutes and briefly press   to store your alarm time

5.3 Alarm function setup:

1.  repeatedly press the   button to check/enable/disable the alarm

  Only “AL” appears: the displayed time is the set alarm time, but the alarm itself is disabled

  “AL” + “ ” appear: the alarm is enabled and the wake-up signal will sound at the set alarm time

  “AL” + “ ” + “ ” appear: the ice alert is set

2.  release the   button; after several seconds the actual time will be displayed again and the alarm 

status as mentioned above remains visible

5.4 Operation:

•  At the set moment of time, the alarm will sound for up to 120 seconds

•  Press the   button to stop the alarm signal beforehand OR press the 

SNOOZE/LIGHT

 button on top 

of the indoor unit to enable the snooze function; the wake-up alarm will sound again after 5 minutes.

•  The alarm is repeated daily until you disable it according to the above instructions OR press and hold 

the 

SNOOZE/LIGHT

 buttons for 2 seconds to delay the alarm for 24 hours.

•  When you enable the ice alert and outside it’s colder than -3°C, the wake-up signal will sound 30 

minutes earlier than the alarm time you set. When it’s warmer than -3°C outside, the alarm will sound 

at the set time.

6. HISTORY
6.1 Introduction:

The indoor unit of the WS-4700 automatically saves all measurement data of the past 24 hours, allowing 

you to check the trend of the last 24 hours at any time

6.2 To view the history:

1.  press the 

HISTORY

 button to show the last saved measurement data in the display, while the upper 

part of the display shows the time and date of the concerned measurement

2.  repeatedly press the 

HISTORY

 button to scroll the memory

The history memory saves the data of the indoor and outdoor temperature and humidity, air pressure, 

wind chill, wind speed and rainfall.

6.3 To delete the history:

Press and hold the HISTORY button for 10 seconds to erase all measurement data up until that 

moment.

Summary of Contents for WS-4700

Page 1: ...User Guide Weather station with wireless outdoor sensor WS 4800 WS 4700 ...

Page 2: ...eriod we guarantee the free repair of defects caused by material and workmanship errors All this subjected to the final assessment of the importer HOW TO HANDLE If you notice any defect first refer to the user s manual If you can t find a decisive answer here please contact your dealer with a clear complaint description The dealer will then accept the product with this proof of warranty and the da...

Page 3: ...tion speed 11 4 8 Feels like Wind chill Heat index Dewpoint 11 4 9 Display lighting 12 5 ALARM CLOCK 5 1 Introduction 12 5 2 Alarm time setup 12 5 3 Alarm function setup 12 5 4 Operation 12 6 HISTORY 6 1 Introduction 12 6 2 To view the history 12 6 3 To delete the history 12 7 MAX MIN ALARM 7 1 Introduction 13 7 2 To set Hi Lo limits 13 7 3 Hi Lo Alarm function setup 13 7 4 Operation 13 8 RELATIVE...

Page 4: ...m clock setup button 12 button alarm setup button 13 button down button 14 button up button 15 C F switch to set the temperature display to degrees Celsius or degrees Fahrenheit 16 Battery compartment 17 RCC button to switch the DCF receiver on or off 18 SCAN button to have the indoor unit search for the outdoor unit 19 RESET button to reboot the indoor unit in case of a possible fault 1 2 5 3 9 8...

Page 5: ... batteries are not recommended because of their lower supply voltage Also the outdoor unit is powered by 3 AA 1 5Volt batteries but because normal Alkaline batteries perform poorly or not at all at temperatures of around or below 0 C it s not recommended to use standard Alkaline batteries for the outdoor unit For that reason we advise you to use Lithium batteries for the outdoor unit that are desi...

Page 6: ...ou can pair the outdoor unit again with the indoor unit as follows 1 press and hold the SCAN button on the indoor unit for 2 seconds until the antenna symbol starts flashing in the display 2 Press briefly press the RESET button on the outdoor unit 3 the units will have found each other again after several seconds 3 3 Positioning reset Indoor unit You may suspend the indoor unit from a simple screw...

Page 7: ...from EN English FR French DE German ES Spanish or IT Italian now briefly press the button 11 use to determine whether the clock must switch to daylight saving time or standard time automatically AUTO or whether you prefer to do this manually OFF now briefly press the button The clock is now set manually When the DCF receiver is enabled and a strong signal is being received the receiver will overwr...

Page 8: ...following moon statuses New moon Full moon Waxing crescent Waning moon First quarter Last quarter Crescent Ashen moon 2 By repeatedly pressing the MAX MIN button the following data will appear in the display in order 1 maximum outdoor temperature 2 minimum outdoor temperature 3 maximum outdoor humidity 4 minimum outdoor humidity 5 maximum indoor temperature 6 minimum indoor temperature 7 maximum i...

Page 9: ...ast is shown Remarks the accuracy of a forecast based on air pressure is 70 to 75 please keep in mind that a correct display of the weather forecast is not guaranteed the prediction is based on the coming 12 hours and does not necessarily represent the current weather conditions the snow weather forecast is based on the air pressure combined with the temperature when the forecast is in fact rain b...

Page 10: ...an change the relative air pressure display in case you re using the weather station on a much higher level than mean sea level 6 In the Benelux one uses the hectoPascal notation Before the air pressure was sometimes also expressed in bar 1 mbar equals 1 hPa You may switch between these notations by briefly pressing the button 4 6 Rain If this window is not visible please first press the button 1 ...

Page 11: ...utside 12 2 temperature according to the indication shown underneath 1 13 3 effect of Wind chill and Heat index on Feels like temperature 12 Feels like temperature compensated with the wind chill or heat index Wind chill combination of the measured temperature and wind speed Heat index combination of the measured temperature and air humidity Dew point temperature outside the temperature at which w...

Page 12: ... Operation At the set moment of time the alarm will sound for up to 120 seconds Press the button to stop the alarm signal beforehand OR press the SNOOZE LIGHT button on top of the indoor unit to enable the snooze function the wake up alarm will sound again after 5 minutes The alarm is repeated daily until you disable it according to the above instructions OR press and hold the SNOOZE LIGHT buttons...

Page 13: ... as the set limit is exceeded an alert tone will sound for up to 2 minutes while the concerned display flashes and the alert indicator underneath the display flashes every 7 seconds Briefly press the button to stop the alert ton The flashing stops automatically as soon as the concerned measurement returns to within the set limits or when you adjust the limit or disable the alarm function for the c...

Page 14: ... 30 anti clockwise making sure that the star sign in the bottom of the funnel is in the Unlock position You can now remove this ring and look at the interior of the rain meter 2 Use a soft brush with long hairs to clean the rain meter 3 Replace the ring onto the rain meter and rotate it clockwise making sure that the star sign in the bottom of the funnel is in the Lock position 10 2 Outdoor temper...

Page 15: ...1100hPa resolution 1hPa 0 01inHg 0 1mmHg accuracy 540 699hPa 8hPa 0 50oC 700 1100hPa 4hPa 0 50oC 405 524mmHg 6mmHg 0 50oC 525 825mmHg 3mmHg 0 50oC 15 95 20 66inHg 0 24inHg 32 122oF 20 67 32 48inHg 0 12inHg 32 122oF forecasts sunny partially cloudy cloudy rain storm snow memory display history of the past 24 hours MIN MAX air pressure with time and date alarm HI LO alarm Wind speed measuring units ...

Page 16: ...vice Help Service Help WWW ALECTO NL SERVICE ALECTO NL Hesdo Australiëlaan 1 5232 BB s Hertogenbosch The Netherlands WWW ALECTO NL SERVICE ALECTO NL Hesdo Australiëlaan 1 5232 BB s Hertogenbosch The Netherlands ...

Reviews: