3
20KG Grease Kit
OWNER’S TECHNICAL MANUAL
G100120
Trouble Shooting
Problem
Possible Causes
Solutions
The pump continues
to operate after the
gun trigger has been
released.
1.
Grease missing around the suction filter.
2.
There is a grease leak at some point
of the circuit.
3.
Valve (part No. 47) closes incorrectly due
to dirt or wearing.
1.
Remove cover and take out pump and follower plate.
Compact grease and fill the drum or replace it for a full one.
2.
Check and tighten unions. Repair the leak.
3.
Disassemble and clean valves. Replace them if damaged.
Reduction of the
grease delivery.
Or reduced pressure
in the grease
delivery.
1.
Air bags in the grease drum.
2.
Silencer (23) dirtied.
3.
Blocked at some point of the grease circuit.
4.
Ball valve (37) closes incorrectly due to dirt
or wearing.
5.
Damaged O-Ring (43).
1.
Remove the cover and take out the pump and the follower
plate. Compact the grease and fill the drum.
2.
Clean or recharge silencer.
3.
Use clean grease.
4.
Replace damaged elements.
Grease leaks through
the air exhaust.
Seal set (28) damaged.
Replace damaged elements.
If the pump has anything wrong, please contact Alemlube.
We do not recommend customers repairing the pump themselves.
Storage and Maintenance
Pumps are delivered in appropriate cardboard boxes. Packaging material should be properly disposed of.
Handling and storage of the pump do not require any special procedures. Dust in the compressed air can slow down
or even block the motor cylinder. The following steps may prevent this from happening:
1. Introduce 50 grams of Vaseline oil or other lubricator into the air inlet hole.
2. Turn on the pump for several minutes until the moving parts are fully lubricated.
3. Repeat the above operation if necessary.
4. The above steps should be carried out on a weekly base.
For the pumps that are attached with compressed air treated equipment please empty the water retained
in the reservoir of the filter-purger frequently.
For the pumps that are attached with a lubricator, please pay close attention to the lubricator’s grease level
and refill with NLGL-2 when necessary.
Note:
The user should perform only routine maintenance operations (such as filters, silencers, cleaning...) in order
not to damage or compromise its safety. Contact Alemlube when the pump needs further maintenance.