3

20KG Grease Kit

OWNER’S TECHNICAL MANUAL

G100120

Trouble Shooting

Problem

Possible Causes

Solutions

The pump continues 
to operate after the 
gun trigger has been 
released.

1.

  Grease missing around the suction filter.

2.

  There is a grease leak at some point  

of the circuit.

3.

  Valve (part No. 47) closes incorrectly due  

to dirt or wearing.

1.

  Remove cover and take out pump and follower plate. 

Compact grease and fill the drum or replace it for a full one.

2.

  Check and tighten unions. Repair the leak.

3.

  Disassemble and clean valves. Replace them if damaged.

Reduction of the 
grease delivery.  
Or reduced pressure 
in the grease 
delivery.

1.

  Air bags in the grease drum.

2.

  Silencer (23) dirtied.

3.

  Blocked at some point of the grease circuit.

4.

  Ball valve (37) closes incorrectly due to dirt 

or wearing.

5.

  Damaged O-Ring (43).

1.

  Remove the cover and take out the pump and the follower 

plate. Compact the grease and fill the drum.

2.

  Clean or recharge silencer.

3.

  Use clean grease.

4.

  Replace damaged elements.

Grease leaks through 
the air exhaust.

Seal set (28) damaged.

Replace damaged elements.

If the pump has anything wrong, please contact Alemlube.  

We do not recommend customers repairing the pump themselves.

Storage and Maintenance

Pumps are delivered in appropriate cardboard boxes. Packaging material should be properly disposed of.  

Handling and storage of the pump do not require any special procedures. Dust in the compressed air can slow down 

or even block the motor cylinder. The following steps may prevent this from happening:
1.  Introduce 50 grams of Vaseline oil or other lubricator into the air inlet hole. 
2.  Turn on the pump for several minutes until the moving parts are fully lubricated.
3.  Repeat the above operation if necessary.
4.  The above steps should be carried out on a weekly base.
For the pumps that are attached with compressed air treated equipment please empty the water retained  

in the reservoir of the filter-purger frequently.
For the pumps that are attached with a lubricator, please pay close attention to the lubricator’s grease level  

and refill with NLGL-2 when necessary.

Note:  

The user should perform only routine maintenance operations (such as filters, silencers, cleaning...) in order 

not to damage or compromise its safety. Contact Alemlube when the pump needs further maintenance.

Summary of Contents for EL SERIES

Page 1: ...less pneumatic greasing solution Should the need ever arise spare parts are readily available upon request Item No G100110 Grease Pump Ratio 50 1 Operating pressure 30 150psi 2 10bar Maximum air inlet pressure 150psi 10bar Air consumption per minute 900 10bar 100L Tube diameter 30mm Suction tube length 480mm Suitable for drum 20kgs Air inlet connection 1 4 quick plug Oil delivery connection Male 1...

Page 2: ...ng this product carefully check that it will operate properly and perform its intended function Check for damaged parts and any other conditions that may affect the operation of this product Replace damaged or worn parts immediately 5 Do not overreach Keep proper footing and balance at all times to prevent tripping falling back injury etc 6 DO NOT use the equipment when tired or under the influenc...

Page 3: ... and fill the drum 2 Clean or recharge silencer 3 Use clean grease 4 Replace damaged elements Grease leaks through the air exhaust Seal set 28 damaged Replace damaged elements If the pump has anything wrong please contact Alemlube We do not recommend customers repairing the pump themselves Storage and Maintenance Pumps are delivered in appropriate cardboard boxes Packaging material should be prope...

Page 4: ...d only to deliver grease Do not use the pump for any other purpose How To Use Pump Installation 1 When the pump is applied to a high viscosity grease or used in low temperature a grease follower plate is recommended to avoid air pockets and to get the most out of your grease The follower plate which is pulled towards the bottom of the drum by suction pressure produced by the air operated pump comp...

Page 5: ... the compressed air feed is connected to the appropriate work pressure level 5 10 bar the pump will start automatically when the nozzle or nozzle situated at the end of the grease delivery circuit is opened To stop the pump simply close the nozzle or disconnect the air inlet line Connect the Pump with other Accessories Part No Description 1 Grease Pump 2 Drum Cover 3 Grease Control Valve 4 Hose wi...

Page 6: ...your hand or body Be sure equipment safety devices are operating properly before each use 4 Any misopertation of the system equipment or accessories such as overpressure modifying parts using incompatible chemicals and fluids or using worn or damaged parts can cause them to rupture and result in fluid injection splashing in the eyes or on the skin or other serious injury or fire explosion or prope...

Page 7: ... Drum Cover and Follower Plate List Put the drum cover onto the drum and tighten the three locks crew Put the follower plate into the grease drum on the grease surface horizontally pressure it as much as possible to exhaust the air between follower plate and grease 50 1 Ratio pump G100110 Drum application 20kgs Drum cover G100110 52 Follower plate G100110 53 1 4 4m connection hose G100110 54 Greas...

Page 8: ...110 12 Baffle 1 G100110 13 Piston 1 G100110 14 O Ring 2 G100110 15 Shaft 1 G100110 16 Shaft 1 G100110 17 Sealing Ring 1 G100110 18 Guiding Ring 1 G100110 19 Connector 1 G100110 20 Silencer 1 G100110 21 O Ring 2 G100110 22 Quick Coupling 1 G100110 23 Silencer 1 G100110 24 Circlip 1 G100110 25 Outlet 1 G100110 26 Air Control Center 1 G100110 27 Washer 1 G100110 28 O Ring 1 G100110 29 Valve Seat 1 G1...

Page 9: ...hing are worn at all times in the vicinity of the control handle Failure to follow these recommendations may result in serious injury or death CAUTION Maximum fluid pressure is 5 800psi 400bar Under no circumstances should the control handle be aimed at any person Personal injury may result Product Description The control handles are used for dispensing automotive lubricants Operation 1 Connect th...

Page 10: ...e 1 O300130 20 Valve Seat 1 O300130 21 Nut 1 O300130 22 O Ring 1 O300130 23 Block Ring 1 O300130 24 Axis Tile 2 O300130 25 Axes 1 O300130 26 Liner Ring 1 O300130 27 Hexad Bolt 4 O300130 28 Join Pipe 2 O300130 29 Join Piece 2 O300130 30 Adjust Bolt 1 O300130 31 Clump Weight 1 O300130 32 Z swivel 1 O300130 1 O300130 2 O300130 3 O300130 4 O300130 7 O300130 8 O300130 30 O300130 6 O300130 9 O300130 10 ...

Reviews: