to Install:

WPL2

 Series

LED Wall Pack

WPL2-IS-0916

A

This product SHALL be surface mounted with 

recessed junction box above 4 feet (1.2 meter) high.
User should prepare necessary accessories and 

spare parts (not provided) including junction box, 

cross bar, junction box gasket, wall fasteners and 

anchors, silicone caulk.

1.

  Attach Mounting Plate (A) using appropriate hardware (supplied by others).  

INSTALLER IS RESPONSIBLE FOR ENSURING PROPER FIXTURE 

ATTACHMENT, INCLUDING SEALING TO THE JUNCTION BOX.

2.  Pull input lead wires through mounting plate hole
 

NOTE: pay special attention to NOT to damage insulation of wires.

3.  Wire AC main leads to fixture input leads.  Make all electrical connections to 

the fixture. 

 

SEE PAGE 1 for Electrical Connection and wiring diagram instructions.

4.  Push wire connections back inside the Junction Box
5.  Angle fixture and slide onto mounting plate into the matching slots on the 

back plate; situate fixture into place on the mounting plate

6.  Ensure no wires are being pinched by the fixture’s metal parts
7.  Tighten the (2) set screws (C) located at the bottom of the fixture until fixture 

is securely fastened

8.  Apply caulk or other sealant (supplied by others) to top and sides of fixture 

where it meets the wall

Surface Mount with Junction Box

A:  Mounting Plate

B:  Junction Box

C:  Set Screws (x2)

E:  Mounting Plate Hole

C

Surface Mount with Conduit

1

5

B

1.  Loosen Screws (D) to open fixture from back plate
2.  Mount fixture back plate to the wall by fastening screws to back plate holes 

(E)

3.  Remove Casting Plug Knockout from side of fixture where conduit will be 

fed.  Feed AC mains into knockout

4.  Wire AC main leads to fixture input leads.  Make all electrical connections to 

the fixture. 

 

SEE PAGE 1 for Electrical Connection and wiring diagram instructions.

5.  Rotate fixture upwards (along hinge) to close fixture back
6.  Slide conduit tube through Casting Plug Knockeout and secure using 

conduit nut.  INSTALLER IS RESPONSIBLE FOR ENSURING PROPER 

FIXTURE ATTACHMENT, INCLUDING SEALING TO THE JUNCTION BOX.

7.  Ensure no wires are being pinched by the fixture’s metal parts
8.  Tighten the (4) screws (D) until fixture is securely fastened
9.  Apply caulk or other sealant (supplied by others) to top and sides of fixture 

where it meets the wall