background image

2 About CM – Connect

The CM Connect is a compact, easy to use, cloud-based gateway and vibration monitoring system
which allows the user to connect and remotely monitor the condition of rotating equipment. The CM
Connect communication is performed wirelessly. Via the built-in cellular solution, internal sensor and
external connectors from critical equipment and application information can be accessed anytime and
anywhere from a PC or handheld device.

The CM Connect can be connected to up to 10 Alfa Laval Condition Monitors (CM) via Bluetooth
which measures equipment vibration and temperature. The measurements are compared against a
baseline set during an initial “Teach” calibration period, which reflects normal condition.

All data and alerts are stored in the cloud and can be accessed for easy record keeping and
troubleshooting.

a

b

c

a) Connected devices and services

b) Cellular 4G data-connection

c) BLE connection up to 10 CM´s per gateway

 NOTE

The CM Connect can be accessed from any browser application and/or through the Alfa Laval CM
Connect App available on the Apple App Store, Google Play Store and Huawei App Gallery. Android
users in China can download the app from the CM Connect product page on alfalaval.cn.

 NOTE

The device is approved for use in the following countries:

United States and The United Kingdom, 

Europe

; Austria, Belgium, Cyprus, Czech Republic,

Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden and The Netherlands,

EFTA

; Switzerland, Iceland, Liechtenstein and Norway.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.

200005871-1-EN-GB

7

EN

www.sks-online.com 

www.sks-webshop.com

Summary of Contents for 8010014918

Page 1: ...Alfa Laval CM Connect Condition Monitor BRITISH ENGLISH 2067 0021 Lit Code 200005871 1 EN GB Manual No 100004444 Instruction manual www sks online com www sks webshop com ...

Page 2: ...ate AB No part of this document may be copied re produced or transmitted in any form or by any means or for any purpose without Alfa Laval Corporate AB s prior express written permission Information and services provided in this document are made as a benefit and service to the user and no representations or warranties are made about the accuracy or suitability of this information and these servic...

Page 3: ...Purpose of this manual 8 2 2 Use of symbols 8 3 Installation 9 3 1 Setting up the CM Connect 11 3 2 Link CM to CM Connect gateway 13 4 Safety 15 4 1 Safety Installation 15 4 2 Product 15 4 3 Recycling information 15 5 Addendum 17 www sks online com www sks webshop com ...

Page 4: ...www sks online com www sks webshop com ...

Page 5: ...52 V1 1 2 2020 Class A EN 301 489 1 V2 2 3 2019 Class A RoHS2 Directive 2011 65 EU Reach US and Canada conformities FCC 47CFR part 15 2020 subpart B Class A ICES 003 2017 Issue 6 Class A The person authorised to compile the technical file is the signer of this document Global Product Quality Manager Hygienic Fluid Handling Lars Kruse Andersen Title Name Signature Kolding 2018 10 01 Commpany Date 2...

Page 6: ...200005871 1 EN GB 6 1 EC Declaration of Conformity EN www sks online com www sks webshop com ...

Page 7: ...vailable on the Apple App Store Google Play Store and Huawei App Gallery Android users in China can download the app from the CM Connect product page on alfalaval cn NOTE The device is approved for use in the following countries United States and The United Kingdom Europe Austria Belgium Cyprus Czech Republic Denmark Estonia Finland France Germany Greece Hungary Ireland Italy Latvia Lithuania Luxe...

Page 8: ... of this manual is to provide necessary information for Installation Safety Recycling Troubleshooting Related documents 2 2 Use of symbols This section describes the symbols used throughout this manual NOTE Note Information considered important to the reader but not related to hazards ATTENTION Attention Informs the reader about a potential hazard if not avoided will result in serious injury HOT S...

Page 9: ...ipment see separate Addendums The CM Connect should be mounted on the wall utilizing two flat or conehead screws not included 86 mm 3 38 x2 5 25 mm 0 21 86 mm 3 38 102 mm 4 02 A B 2067 0022 116 mm 4 56 40 mm 1 57 A Power supply connector B External sensors connector Future options Power supply specifications 24VDC 7 15W 200005871 1 EN GB 9 EN www sks online com www sks webshop com ...

Page 10: ...ue PIN4 Future option Power connector cables can be ordered through Alfa Laval using following article numbers Cable M12 4 wire female straight connector 5m 15Ft length For wall mount 8010000288 Cable M12 4 wire female straight connector 10m 30Ft length For wall mount 8010000289 200005871 1 EN GB 10 3 Installation EN www sks online com www sks webshop com ...

Page 11: ... alfalaval cn 2067 0024 For PC For mobile device 1 2 and open the 3 CM Connect product page on 4 1 New user Press First time log in and follow the instructions on the screen 2 For existing user Login with current credentials Press Register new CM Connect and enter the device ID see where you find the device ID below Follow the instructions on the screen 2067 0025 5 Click Register Device for activa...

Page 12: ...le blinking led b Connected to cellular network Double blinking led c Connected to CM Connect server Pulsating heartbeat led ON OFF 2067 0027 ON OFF ON OFF a b c 7 If there are any issues during the registration process please contact Alfa Laval Customer Support connectsupport alfalaval com 200005871 1 EN GB 12 3 Installation EN www sks online com www sks webshop com ...

Page 13: ...028 2 A list of available CM s will appear in the devices in range list 2067 0029 3 Use the wink functionality to easily identify one CM from another Selecting Wink will instruct the CM to flash purple every second for a total of 2 minutes enabling the user time to visually locate and assign the CM to the correct CM Connect within the user interface 200005871 1 EN GB 13 Installation 3 EN www sks o...

Page 14: ...200005871 1 EN GB 14 3 Installation EN www sks online com www sks webshop com ...

Page 15: ...uch as pump gearboxes be aware of potential hot surfaces and always wear appropriate protective equipment The CM Connect can be mounted on surfaces up to 80 C 176 F 4 2 Product Attention Only expose the CM Connect to ambient temperatures within 30 to 70 22 F to 158 F Heating above these temperatures could result in serious injury Never dispose of the CM Connect in a fire this could result in serio...

Page 16: ...200005871 1 EN GB 16 4 Safety EN www sks online com www sks webshop com ...

Page 17: ...5 Addendum Alfa Laval Specific Equipment Installation Guidelines 200005871 1 EN GB 17 EN www sks online com www sks webshop com ...

Reviews: