7
Operating instructions
If using the suction device with bellows (option),
check that the top is located just under the
surface in the tank so that the surface layer
is sucked into the bellows. The setting is
self-adjusted.
G0986981
4. Increase the counter pressure slowly until a
small stream of oil/ liquid is observed coming
from the oil outlet (1). Preferably, use a torchlight
to see this. Reduce the counter pressure to
increase the oil concentration or increase the
counter pressure to improve the oil removal
efficiency of the separator.
5. After adjustment of the counter pressure,
check that the pressure is within the
recommended range (100 - 180 kPa).