8
Trouble shooting
8.6
Separator vibrates
!
WARN
ING
Disintegration hazard
If excessive vibrations occur,
STOP
the separator
Possible cause
Action
Bowl out of balance due to:
•
Insufficient or incorrect cleaning
(sludge in disc stack)
•
Unevenly spaced sludge cake (bowl
not cleaned prior to start)
•
Incorrect assembly
Dismantle and clean the separator bowl. Be
sure that the separator is assembled correctly.
Vibration dampers in separator are worn
Fit new dampers
Damaged bearings
Replace the bearings
8.7
No flow from pump
Possible cause
Action
Incorrect setting of flow control (too low
speed of pump)
Start with max. flow. See
.
The screw fitted in pump is not closed
(internal leakage too high)
Turn the adjustment screw clockwise.
Air leakage on suction side between tank
and pump
Check that the inlet is below surface in tank.
Check that couplings are correctly fitted.
39